Effects of Open and Closed System Endotracheal Suctioning Methods on Suctioning Frequency and Amount of Secretion
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 100
- 试验地点
- 1
- 主要终点
- frequency of suctioning
研究概览
简要总结
Tracheal suctioning is a process which is often applied to patients' care who have an artificial airway and whose respiration is achieved via mechanical ventilation. When secretions are not cleaned enough, it causes a variety of complications in the patient from hypoxemia to infection.
It is reported that the studies with nurses in clinical practice have shown that they have opinions such as the closed system does not suction the patients effectively as the open system does; it remains incapable in removing secretions, thus the suctioning process is being applied more frequently.
Therefore this study is designed to examine the amount of secretions and frequency of suctioning as a result of open and closed suctioning systems.
详细描述
Patients will be monitored for two days. On the first day, the patient will be followed up with an open system and the second day closed suctioning system will be used, or the patient will be followed up with a closed system on the first day and followed with an open system on the second day. The patients are randomly allocated on the first follow up days. The follow-up period has two consecutive days. suctioning will be performed for 12 hours in one day. The number of suctions will be recorded. The amount of secretion will be accumulated in the mucus collection vessel. At the end of the day, the secretion will be weighed with precision weighing.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Health Services Research
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •orally intubated in first 96 hours
- •stabilized patients in conditionally
- •platelets > 50.000
- •not have hemorrhagic secretions
排除标准
- •hemodynamically unstabilized patients
研究组 & 干预措施
closed suctioning system
Closed suctioning system will be compared with open suctioning system
干预措施: closed suctioning system (Procedure)
open suctioning system
The patient will be monitored with closed system for one day and open aspiration system on the other day.
结局指标
主要结局
frequency of suctioning
时间窗: 12 hours of a day
frequency of suctioning in a half of a day
amount of secretion
时间窗: 12 hours of a day
amount of secretion in a half of a day
次要结局
- spo2(12 hours of a day)
- tidal volume(12 hours of a day)
研究者
Ilkin Yilmaz
Research Assisstant
Dokuz Eylul University