临床试验/NCT04779294
NCT04779294已完成不适用

The Oslo Stan vs Lactate Observational Study, an Observational Study Were we Compare the Clinical Performance of Two Adjunctive Methods to CTG in Intrapartum Fetal Monitoring

Oslo University Hospital1 个研究点 分布在 1 个国家目标入组 694 人开始时间: 2018年9月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
694
试验地点
1
主要终点
Is fetal hypoxia (defined as arterial umbilical cord pH < 7,1 postpartum) superiorly identified by fetal scalp blood sampling (lactate) or ST analysis of fetal ECG

研究概览

简要总结

The main aim of the study is to compare the clinical performance of two adjunctive methods to CTG in intrapartum fetal monitoring: FBS with measurement of scalp lactate and ST analysis of the fetal ECG.

详细描述

We use Lactate as a standard adjunctive method in our hospital but we have STAN software available ( is demasked) in our CTG monitors. We will include all women in labour with an intern scalp monitoring and analyse the CTG, the lactate samples and the STAN signals in the same patient and

  • Study the relationship between the decision-to-delivery interval and neonatal morbidity in deliveries monitored by scalp lactate measurement
  • Compare the diagnostic capability of both methods to identify fetuses at risk of hypoxia
  • Compare the false negative alerts from both methods
  • Explore the temporal and quantitative relation between fetal lactate metabolism and ST interval changes of the fetal ECG

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 60 Years(Adult)
性别
Female
接受健康志愿者

入选标准

  • Singleton pregnancy
  • Cephalic presentation
  • Gestational age ≥36+0 weeks at delivery
  • Presence of antpartum or intrapartum risk factors for fetal hypoxia according to Norwegian guidelines and therefore indication for electronic fetal monitoring with scalp electrode .

排除标准

  • Multiple pregnancies
  • Breech presentation
  • Gestational age < 36+0 weeks
  • Contraindications for placement of a scalp electrode (HIV or HBV or HCV pos)

结局指标

主要结局

Is fetal hypoxia (defined as arterial umbilical cord pH < 7,1 postpartum) superiorly identified by fetal scalp blood sampling (lactate) or ST analysis of fetal ECG

时间窗: 2019-2022

1. Compare the diagnostic capability of both methods to identify fetuses at risk of hypoxia (i.e.umbilical artery blood pH ≤7.1) 2. Compare FBS lactate with STAN in order to identify the superior method to avoid cord-blood acidosis at birth (i.e.umbilical artery blood pH \>7.1) 3. Compare the true negative alerts from both methods, specificity

Is cord blood acidosis, measured as pH in the umbilical artery postpartum affected by the "Decision-to-delivery interval" measured in minutes from Lactate warning until delivery.

时间窗: 2019-2022

To assess the effect of increasing time interval from the objective warning of intrapartum fetal hypoxia with fetal scalp lactate ≥ 4.8mmol/l to the end of operative delivery on the percentage of moderate cord-blood acidosis at birth (i.e., umbilical artery blood pH ≤ 7.1)

次要结局

未报告次要终点

研究者

发起方
Oslo University Hospital
申办方类型
Other
责任方
Principal Investigator
主要研究者

Anne Flem Jacobsen

Senior Consultant, dpt of Obstetrics, Prof II University of Oslo