跳至主要内容
临床试验/NCT04956172
NCT04956172已完成不适用

Assessing the Impact of the NeuroCatch Platform 2 Stimulus Tone Volume

NeuroCatch Inc.2 个研究点 分布在 1 个国家目标入组 18 人开始时间: 2021年7月12日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
18
试验地点
2
主要终点
Difference in latency of the P300 ERP

研究概览

简要总结

The NeuroCatch Platform 2 (NCP2), an investigational medical device system developed by NeuroCatch Inc., consists of software and hardware that captures brain health information. The platform intends to provide a quick, portable and easy to use solution for the acquisition, display, analysis, storage, reporting and management of electroencephalograph (EEG) and event-related potential (ERP; brain response to a stimulus) information.

The NCP2 uses two types of tones to elicit N100 and P300 ERPs, along with two types of words to elicit N400 ERPs. The objective of this study is to determine if changing the volume of the standard tone has an effect on the amplitudes and latencies of the ERPs.

详细描述

Electroencephalography (EEG) signals have been collected and studied since the early 1970s as a non-invasive way of assessing brain function. As early as the 1930s, a derivative of the raw EEG signal - event-related potentials (ERPs) - were computed. These scalp-recorded ERPs are the brain's response to a stimulus of interest (e.g. a flashing checkerboard or an angry face). The size, timing, and topographical location of ERP components lend insight into the timing and complexity of various cognitive processes. At NeuroCatch Inc. (NCI), research is primarily focused on three ERP components: the N100, P300 and N400, associated with different attention abilities (sensory processing, target detection & semantic processing).

The N100 is a negative-going deflection around 100 ms post stimulus onset. This particular ERP component indexes sensory stimulus at a pre-attentive level, or in other words, the acknowledgement by the brain that information has entered the system. Whereas the P300 - a positive-going deflection around 300 ms - indexes an early stage of attentional processing. This component is particularly sensitive to context updating or target identification (the brain's 'Ah-ha!' response). Finally, the N400 is a negative-going deflection peaking around 400 ms post stimulus. This component is measured in situations of semantic violations (e.g. 'The pizza was too hot to ... lamp"), thus indexing one of the highest-order cognitive functions: language processing.

Each of the three ERP components have been studied in academic laboratories for multiple decades and prototypical values for their timing (latency) and size (amplitude) have become widely accepted. To elicit the ERP components of interest in this study (N100, P300, N400), proprietary auditory stimulus sequences will be administered using the NeuroCatch Platform 2, an investigational medical device. Each sequence consists of tones and word pairs to elicit the various components of interest. Standard tones (lower volume, low pitch) make up most of the tones in the sequence, with deviant tones (higher volume, higher pitch) inserted in random intervals. The difference in volume and pitch between the standard tones and deviant tones, coupled with the "unexpected" nature of the deviant tone, is what drives the N100 and P300 responses.

NeuroCatch Platform 2 consists of a computerized acquisition software which presents the stimulus, acquires the data and presents the amplitude and latency values of the ERP components (N100, N400, P300). This protocol is intended to assess the effect of changing the standard tone volume in the NeuroCatch Platform 2 auditory tone sequences on the elicited ERP responses.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Other
盲法
Single (Participant)

盲法说明

Participants are not informed the order or type (standard Tone A, standard Tone B) of the sequences

入排标准

年龄范围
19 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Any sex, at least 19 years of age or older
  • Able to understand the informed consent form, study procedures and willing to participate in study
  • Able to remain seated and focused for 7 minutes
  • In good health with no history of clinically relevant neurological illness or injury in the last 5 years

排除标准

  • Requires the use of hearing aids or a cochlear implant, diagnosed with tinnitus that is currently active, or has temporary damage to hearing (e.g. punctured ear drum).
  • Implanted pacemaker or implanted electrical stimulators
  • Metal or plastic implants in the skull, excluding dental/facial implants.
  • Exposed to an investigational drug or device 30 days prior to start in this study, or concurrent or planned use of investigational drug or device while enrolled in this study
  • Not proficient in English language
  • Diagnosed epilepsy or history of seizures
  • If female and of child-bearing potential: pregnant, suspected or planning to become pregnant or breast-feeding
  • Unhealthy scalp (apparent open wounds and/or bruised or weakened skin)
  • Allergy to EEG gel or history of contact dermatitis

结局指标

主要结局

Difference in latency of the P300 ERP

时间窗: 1 week (6-8 days)

Latency (response time) will be measured in microseconds. The statistic being used to measure the difference in amplitude between the two Tone types will be a full-factorial repeated measures analysis of variance (Factors: Tone type, Session number, Run number)

Difference in amplitude of the N400 ERP

时间窗: 1 week (6-8 days)

Amplitude (response size) will be measured in microvolts. The statistic being used to measure the difference in amplitude between the two Tone types will be a full-factorial repeated measures analysis of variance (Factors: Tone type, Session number, Run number)

Difference in latency of the N400 ERP

时间窗: 1 week (6-8 days)

Latency (response time) will be measured in microseconds. The statistic being used to measure the difference in amplitude between the two Tone types will be a full-factorial repeated measures analysis of variance (Factors: Tone type, Session number, Run number)

Difference in amplitude of the P300 ERP

时间窗: 1 week (6-8 days)

Amplitude (response size) will be measured in microvolts. The statistic being used to measure the difference in amplitude between the two Tone types will be a full-factorial repeated measures analysis of variance (Factors: Tone type, Session number, Run number)

Difference in amplitude of the N100 ERP

时间窗: 1 week (6-8 days)

Amplitude (response size) will be measured in microvolts. The statistic being used to measure the difference in amplitude between the two Tone types will be a full-factorial repeated measures analysis of variance (Factors: Tone type, Session number, Run number)

Difference in latency of the N100 ERP

时间窗: 1 week (6-8 days)

Latency (response time) will be measured in microseconds. The statistic being used to measure the difference in amplitude between the two Tone types will be a full-factorial repeated measures analysis of variance (Factors: Tone type, Session number, Run number)

次要结局

  • Repeatability of the P300 Latency for Tone A(1 week (6-8 days))
  • Repeatability of the N100 Amplitude for Tone A(1 week (6-8 days))
  • Repeatability of the N100 Latency for Tone A(1 week (6-8 days))
  • Repeatability of the N100 Latency for Tone B(1 week (6-8 days))
  • Collection and evaluation of adverse events and adverse device effects(At time of event)
  • Repeatability of the N100 Amplitude for Tone B(1 week (6-8 days))
  • Repeatability of the N400 Latency for Tone B(1 week (6-8 days))
  • Repeatability of the N400 Amplitude for Tone A(1 week (6-8 days))
  • Repeatability of the P300 Amplitude for Tone A(1 week (6-8 days))
  • Repeatability of the P300 Amplitude for Tone B(1 week (6-8 days))
  • Repeatability of the P300 Latency for Tone B(1 week (6-8 days))
  • Repeatability of the N400 Amplitude for Tone B(1 week (6-8 days))
  • Repeatability of the N400 Latency for Tone A(1 week (6-8 days))

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验