Evaluation of the Performance of the Ventilation-filtration System for Operating Rooms at the Protestant Hospital of Mbouo-Bandjoun (VENTI-MBOUO)

Christian Doll1 个研究点 分布在 1 个国家目标入组 1 人开始时间: 2024年5月29日最近更新:

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
1
试验地点
1
主要终点
air pressure

研究概览

简要总结

This research project is evaluating an air filtration system that is supposed to be adapted to the context, highly efficient and affordable. This air filtration system for operating theatres has been in use at Mbouo-Bandjoun hospital in Cameroon since 2019, with no incidents recorded to date.

In this proposed research project, only the ventilation system will be tested technically and microbiologically; no research will be carried out directly on patients or with patient participation.

Therefore, the research project is not expected to have any impact on patients. Technical test data will be evaluated retrospectively, while microbiological data will be collected prospectively without patient contact.

The air filtration system was installed in the OT of the Protestant hospital Mbouo (Hôpital Protestant de Mbouo) in 2019. Before the installation of the air filtrations system, the OT used window-based ventilation which seems, besides wall-mounted air conditioning systems, quite common in OT in Cameroonian hospitals.

The air filtrations system has been in regular use for 3.5 years before the first maintenance could be performed, due to COVID travel restrictions. This maintenance and technical measurement took place in November 2023.

Microbial samples in the OT were collected in Mai 2024. The data of the maintenance and technical measurements of the air filtration system are retrospectively used for this study. The parameters that are extracted from the maintenance documents are: particle counts, temperature, humidity, air velocity and pressure differences at various measurement points inside and outside the OT as well as inside the air filtration device.

To study the microbial burden in the OT, a prospective evaluation was carried out: In a time slot when no surgical procedures were planned, a passive sampling with settling plates was carried out.

详细描述

Abstract

The research project is entitled "Evaluation of the performance of the ventilation-filtration system for operating rooms at the Protestant Hospital of Mbouo-Bandjoun (VENTI-MBOUO)".

This research project evaluates an air filtration system supposedly adapted to the context, assumed to be very effective and at low cost. This operating theater air filtration system has been used at Mbouo-Bandjoun hospital for almost 4 years, without any incident problems having been recorded so far.

In this proposed research project, only the filtration-ventilation system will be tested technically and microbiologically; no research will be carried out directly on patients or with patient participation.

Therefore, the research project is not expected to have any impact on patients. Technical test data will be evaluated retrospectively, microbiological data will be collected prospectively in May 2024, without contact with the patient.

研究设计

研究类型
Observational
观察模型
Ecologic Or Community
时间视角
Other

入排标准

性别
All
接受健康志愿者

入选标准

  • No patients, only a technical/microbial assessment of the ventilation-filtration system in the operating theatre, with no contact with patients; therefore no source population and no inclusion criteria

排除标准

  • No patients, only a technical/microbial assessment of the ventilation-filtration system in the operating theatre, with no contact with patients; therefore no source population and no exclusion criteria

结局指标

主要结局

air pressure

时间窗: retrospective: 4 years before study start

air pressure (kPa) in the operating theatre and in the air filtration system.Retrospective variable

microbial air contamination

时间窗: prospective: 29 april to 31 april 2024

Changes in microbial contamination of the air in the operating theatre after the ventilation-air filtration system was switched on, during periods of inactivity in the operating theatre, without any contact with the patient (colony-forming units per Petri dish).Prospective variable

number of particles in the operating room air

时间窗: retrospective: 4 years before study start

The number of particles in the operating room air (particles per litre of air). Retrospective variable.

maintenance frequency

时间窗: retrospective: 4 years before study start

Maintenance of the ventilation-filtration system carried out over the last 4 years (frequency). Retrospective variable

system breakdowns

时间窗: retrospective: 4 years before study start

Number of system breakdowns. Retrospective variable

air speed and direction

时间窗: retrospective: 4 years before study start

Air speed (m/s) and air direction in the operating theatre and in the air filtration system.Retrospective variable