跳至主要内容
临床试验/NCT03248232
NCT03248232已完成不适用

AssessmenTs of ThRombogenicity for trAnsCatheter aorTIc valVE Implantation by Total Thrombus-formation Analysis System (ATTRACTIVE-TTAS)

Kumamoto University1 个研究点 分布在 1 个国家目标入组 23 人开始时间: 2017年8月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
23
试验地点
1
主要终点
Changes in T-TAS parameters (AR-chip, PL-chip) during TAVI

研究概览

简要总结

Transcatheter aortic valve implantation (TAVI) is well established, and can improve clinical outcomes of patients with severe aortic valve stenosis (AS) who are inoperable or have high surgical risk. Although the rates of periprocedural bleeding events are lower in TAVI compared to those in surgical aortic valve replacement, those in TAVI still remains high. In addition, current guideline recommended the dual antiplatelet (DAPT), clopidogrel plus aspirin, for a 3- to 6-month period after TAVI, however no evidences supports this approach. The antithrombotic regimen in patients undergoing TAVI is needed to be established.

To establish the antithrombotic regimen in patients undergoing TAVI,

  1. the investigators assess the changes in platelet thrombus formation and white thrombus formation in patients undergoing TAVI measured by Total Thrombus Formation Analysis System (T-TAS).
  2. the investigators analyze plasma microRNAs, and shear stress by using computational fluid dynamics (CFD) to clarify the mechanistic factors regarding those changes.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
20 Years 至 100 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • twenty years and older
  • with the informed consent of the patient or support person in case of disability at baseline (patient intubated and ventilated)

排除标准

  • withdrawn the informed consent
  • patients with trans-apical approach
  • critical illness condition (severe infectious disease, cancer, severe bleeding disorder)
  • transition to the surgical AVR

结局指标

主要结局

Changes in T-TAS parameters (AR-chip, PL-chip) during TAVI

时间窗: pre-, day 2, day 7, 1 month after device implantation

To measure the thrombus formation area under the curve for AR-chip (AR10-AUC30), and PL-chip (PL24-AUC10) before and after TAVI.

次要结局

  • Periprocedural complication, particularly, bleeding complication defined by VARC-2 criteria.(within 30 days after device implantation)
  • Changes in shear stress analyzed by using CFD analysis of contrast-enhanced CT(pre-, day 7 after device implantation)
  • Changes in von Willebrand factor multimer decrease(pre-, day 2 after device implantation)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Kenichi Tsujita, MD, PhD

Professor of Cardiovascular Medicine, Principal Investigator

Kumamoto University

研究点 (1)

Loading locations...

相似试验