临床试验/NCT01901744
NCT01901744已完成不适用

Contrast Sensitivity Assessment in Pediatric Cataract Surgery With IOL Implantation: A Comparison of Preoperative and Early Postoperative Outcomes

Iladevi Cataract and IOL Research Center2 个研究点 分布在 1 个国家目标入组 25 人开始时间: 2009年1月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
25
试验地点
2
主要终点
Contrast Sensitivity at 3, 6, 12 and 18 cycles per degree under photopic and mesopic conditions pre and post cataract surgery

研究概览

简要总结

The study evaluates contrast sensitivity in older children following surgery for lamellar and posterior subcapsular cataracts. Often, pediatric surgeons tend to delay surgery in these children who present beyond the amblyogenic age group. These cataracts are often compatible with reasonable visual acuity and therefore some surgeons prefer to wait for surgery, whereas others tend to operate.

The study evaluates improvement in contrast sensitivity at different spatial frequencies following cataract surgery for lamellar and posterior subcapsular cataracts in older children.

详细描述

All patients undergoes temporal clear corneal incision, manual anterior continuous curvilinear capsulorhexis, bimanual irrigation/aspiration for lens removal and residual cortex, posterior capsule management based on the age of the patient either manual posterior capsulorhexis (PCCC) upto 6 years or leaving intact posterior capsule and implantation of single-piece AcrySof SN60WF (Alcon Laboratories, Forth Worth, Texas) hydrophobic acrylic IOL in-the-bag. Postoperatively, all the patients are examined first for high contrast sensitivity and then for low contrast at 1 week, 1 and 3 months respectively.

The results are analyzed for corrected distance visual acuity (CDVA) which is recorded in LogMAR units at preoperative and 1 and 3 months postoperatively. Monocular high-contrast Snellen visual assessment for distance is done with the Early Treatment Diabetic Retinopathy Study chart (Vector Vision acuity chart at 100% contrast) with Corrected distance visual acuity CDVA at 4 m under photopic condition.

Similarly at preoperative and 1 and 3 months postoperatively contrast sensitivity testing is also performed using the CSV 1000E sine wave grating test face (Vector Vision, USA) with the patient seated at a distance of 2.5 m from the chart. The test is performed after the patient is adapted to the room luminance for 5 minutes. The non viewing eye was occluded for each measurement, and the best spectacle refractive correction is placed in front of the viewing eye. Testing is being tested under two lighting conditions: photopic (85cd/m2) and mesopic (2.7cd/m2). The contrast sensitivity values are documented in log units. Sensitivity levels at each frequency range from 0.7 to 2.08 (3 cpd), 0.91 to 2.29 (6 cpd), 0.61 to 1.99 (12 cpd), and 0.17 to 1.55 (18 cpd) log units. This testing is performed with the patient wearing their refractive correction in form of spectacles.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
1 Year 至 15 Years(Child)
性别
All
接受健康志愿者

入选标准

  • Children older than 4 years and lamellar and posterior subcapsular cataracts undergoing cataract surgery with IOL implantation

排除标准

  • eyes with traumatic or subluxated cataract,

结局指标

主要结局

Contrast Sensitivity at 3, 6, 12 and 18 cycles per degree under photopic and mesopic conditions pre and post cataract surgery

时间窗: up to 3 months postoperatively

Preoperative and 1 and 3 months postoperatively contrast sensitivity testing would performed using the CSV 1000E sine wave grating test face (Vector Vision, USA) with the patient seated at a distance of 2.5 m from the chart. The test is performed after the patient was adapted to the room luminance for 5 minutes. The non viewing eye is occluded for each measurement, and the best spectacle refractive correction is placed in front of the viewing eye. Testing is performed at preoperative 3, 6, 12 and 18 cycles per degree, each spatial frequency being tested under two lighting conditions: photopic (85cd/m2) and mesopic (2.7cd/m2). The contrast sensitivity values are documented in log units. Sensitivity levels at each frequency range from 0.7 to 2.08 (3 cpd), 0.91 to 2.29 (6 cpd), 0.61 to 1.99 (12 cpd), and 0.17 to 1.55 (18 cpd) log units. This testing is performed with the patient wearing their refractive correction in form of spectacles.

次要结局

  • Improvement in Best Corrected Snellen's Visual Acuity following Cataract Surgery(1 and 3 months postoperatively)

研究者

发起方
Iladevi Cataract and IOL Research Center
申办方类型
Other
责任方
Principal Investigator
主要研究者

Abhay R. Vasavada

Director, Iladevi Cataract and IOL Research Center

Iladevi Cataract and IOL Research Center