18F-GP1 Positron Emission Tomography-computed Tomography to Detect Bioprosthetic Aortic Valve Thrombosis; the Biothrombus Study.
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 53
- 试验地点
- 1
- 主要终点
- Prevalence of 18F-GP1 PET-CT bioprosthetic aortic valve uptake
研究概览
简要总结
18F-GP1 binds with high affinity to the glycoprotein IIb/IIIa receptors on activated platelets. 18F-GP1 PET-CT has recently demonstrated favourable safety, pharmacokinetic, biodistribution and diagnostic performance for the in vivo identification of venous and arterial thrombemboli.
详细描述
Aortic stenosis is the most common reason for valvular interventions in the developed world, with rates projected to increase as the population ages. Aortic valve replacement remains the only recognised treatment available. Bioprostheses are far more common than mechanical prostheses, particularly with increasing rates of transcatheter heart valve use.
Bioprothetic valves are less durable than mechanical valves and are subject to deterioration which may lead to clinical heart failure and the need for re-intervention. Long-term results with surgical bioprostheses are well reported, with valve deterioration rates of less than 15% at 10 years. These data, however, rely on re-operation rather than echocardiographic measures, suggesting that the true incidence of structural valve deterioration is underestimated.
Valve thrombosis is increasingly recognised as a potential contributor to leaflet degeneration and has been detected in participants undergoing both surgical aortic valve replacement and transcatheter aortic valve implantation. The role of valve thrombosis as an early trigger for calcification and subsequent valve degeneration has not been addressed. The true incidence of valve thrombosis and its impact on clinical outcomes is unknown due to the lack of a sufficiently sensitive non-invasive imaging modality to detect early subclinical thrombosis. Current observational data suggests rates of 12 to 40%, based on computed tomography findings. There is a clinical need for a more sensitive non-invasive method of detecting valve thrombosis.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 50 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •ability to give informed consent
- •>1 month post-surgical or transcatheter aortic valve replacement
排除标准
- •Inability to give informed consent
- •Pregnancy or breastfeeding
- •Contraindications to iodinated contrast
- •Contraindications to anticoagulation
- •Use of anticoagulants during the post-operative period prior to screening
- •Extreme claustrophobia
- •Chronic kidney disease (with estimated glomerular filtration rate <30 mL/min/1.73m2)
- •Metastatic malignancy
- •Inability to tolerate the supine position
结局指标
主要结局
Prevalence of 18F-GP1 PET-CT bioprosthetic aortic valve uptake
时间窗: 2 years
Prevalence of 18F-GP1 PET-CT bioprosthetic aortic valve uptake as measured by standardised uptake values.
Intensity of 18F-GP1 PET-CT activity in bioprosthetic aortic valve thrombus
时间窗: 2 years
Intensity of 18F-GP1 PET-CT activity in bioprosthetic aortic valve thrombus compared to blood pool as measured by standardised uptake values.
次要结局
- 18F-GP1 PET-CT bioprosthetic aortic valve uptake in patients with thrombus.(2 years)