An Open-label, Randomized, Two-way, Cross-over Study to Assess the Efficacy of Single-hormone Closed-loop Strategy and Sensor-augmented Pump Therapy in Regulating Glucose Levels for 5 Days in Free-living Outpatient Conditions in Patients With Type 1 Diabetes

Institut de Recherches Cliniques de Montreal1 个研究点 分布在 1 个国家开始时间: 2018年3月最近更新:
适应症
干预措施
相关药物

试验速览

阶段
2 期
状态
撤回
发起方
试验地点
1
主要终点
Percentage of time of glucose levels spent between 3.9 and 10.0 mmol/L

研究概览

简要总结

Closed-loop strategy is composed of three components: glucose sensor to read glucose levels, insulin pump to infuse insulin and a dosing mathematical algorithm to decide on the required insulin dosages based on the sensor's readings.

The main objective of this project is to compare the efficacy of single-hormone closed-loop strategy and sensor-augmented pump therapy to regulate glucose levels in outpatient settings for 5 consecutive days in adults with type 1 diabetes.

The investigators hypothesized that single-hormone closed-loop strategy will increase the time spent in the target range compared to sensor-augmented pump therapy.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Males and females ≥ 18 years of old.
  • Clinical diagnosis of type 1 diabetes for at least one year.
  • The subject will have been on insulin pump therapy for at least 3 months.
  • HbA1c ≤ 10%.
  • Live in the area of Montreal.

排除标准

  • Clinically significant nephropathy, neuropathy or retinopathy as judged by the investigator.
  • Recent (< 6 months) acute macrovascular event e.g. acute coronary syndrome or cardiac surgery.
  • Warfarin chronic treatment if INR monitoring cannot be evaluated (can increase the risk of bleeding)
  • Pregnancy (ongoing or current attempt to become pregnant).
  • Severe hypoglycemic episode within two weeks of screening.
  • Current use of glucocorticoid medication (except low stable dose and inhaled steroids).
  • Known or suspected allergy to the trial products
  • Other serious medical illness likely to interfere with study participation or with the ability to complete the trial by the judgment of the investigator.
  • Anticipating a significant change in exercise regimen between admissions (i.e. starting or stopping an organized sport).

研究组 & 干预措施

Sensor-augmented pump therapy

Active Comparator

Participants will use sensor-augmented pump therapy with low-glucose suspend to regulate glucose levels. The low-glucose suspend feature available in the MiniMed® Paradigm® Veo™, Medtronic combined with the Enlite sensor® will be used. This feature allows for suspension of insulin delivery at a pre-set sensor glucose value for up to 2 hours.

干预措施: 5-day intervention with sensor-augmented pump therapy (Other)

Sensor-augmented pump therapy

Active Comparator

Participants will use sensor-augmented pump therapy with low-glucose suspend to regulate glucose levels. The low-glucose suspend feature available in the MiniMed® Paradigm® Veo™, Medtronic combined with the Enlite sensor® will be used. This feature allows for suspension of insulin delivery at a pre-set sensor glucose value for up to 2 hours.

干预措施: Insulin pump (Device)

Sensor-augmented pump therapy

Active Comparator

Participants will use sensor-augmented pump therapy with low-glucose suspend to regulate glucose levels. The low-glucose suspend feature available in the MiniMed® Paradigm® Veo™, Medtronic combined with the Enlite sensor® will be used. This feature allows for suspension of insulin delivery at a pre-set sensor glucose value for up to 2 hours.

干预措施: Continuous glucose monitoring system (Device)

Sensor-augmented pump therapy

Active Comparator

Participants will use sensor-augmented pump therapy with low-glucose suspend to regulate glucose levels. The low-glucose suspend feature available in the MiniMed® Paradigm® Veo™, Medtronic combined with the Enlite sensor® will be used. This feature allows for suspension of insulin delivery at a pre-set sensor glucose value for up to 2 hours.

干预措施: Insulin (Drug)

Single-hormone closed-loop strategy

Active Comparator

Variable subcutaneous insulin infusion will be used to regulate glucose levels. Participant's usual fast-acting insulin analog will be infused using a subcutaneous infusion pump (MiniMed® Paradigm® Veo™, Medtronic). Every 10 minutes, the glucose levels as measured by the sensor (Enlite sensor®, Medtronic) will be transferred automatically to a smartphone, that harbors the algorithm, that will calculate the recommended doses and will send it wirelessly to the infusion pump.

干预措施: 5-day intervention with single-hormone closed-loop strategy (Other)

Single-hormone closed-loop strategy

Active Comparator

Variable subcutaneous insulin infusion will be used to regulate glucose levels. Participant's usual fast-acting insulin analog will be infused using a subcutaneous infusion pump (MiniMed® Paradigm® Veo™, Medtronic). Every 10 minutes, the glucose levels as measured by the sensor (Enlite sensor®, Medtronic) will be transferred automatically to a smartphone, that harbors the algorithm, that will calculate the recommended doses and will send it wirelessly to the infusion pump.

干预措施: Insulin pump (Device)

Single-hormone closed-loop strategy

Active Comparator

Variable subcutaneous insulin infusion will be used to regulate glucose levels. Participant's usual fast-acting insulin analog will be infused using a subcutaneous infusion pump (MiniMed® Paradigm® Veo™, Medtronic). Every 10 minutes, the glucose levels as measured by the sensor (Enlite sensor®, Medtronic) will be transferred automatically to a smartphone, that harbors the algorithm, that will calculate the recommended doses and will send it wirelessly to the infusion pump.

干预措施: Continuous glucose monitoring system (Device)

Single-hormone closed-loop strategy

Active Comparator

Variable subcutaneous insulin infusion will be used to regulate glucose levels. Participant's usual fast-acting insulin analog will be infused using a subcutaneous infusion pump (MiniMed® Paradigm® Veo™, Medtronic). Every 10 minutes, the glucose levels as measured by the sensor (Enlite sensor®, Medtronic) will be transferred automatically to a smartphone, that harbors the algorithm, that will calculate the recommended doses and will send it wirelessly to the infusion pump.

干预措施: Insulin (Drug)

结局指标

主要结局

Percentage of time of glucose levels spent between 3.9 and 10.0 mmol/L

时间窗: 120 hours

次要结局

  • Percentage of time of overnight glucose levels spent below 2.8 mmol/L(35 hours)
  • Percentage of time of overnight glucose levels spent above 10 mmol/L(35 hours)
  • Percentage of time of overnight glucose levels spent above 13.9 mmol/L(35 hours)
  • Percentage of time of overnight glucose levels spent above 16.7 mmol/L(35 hours)
  • Area under the curve of glucose levels below 3.9 mmol/L(120 hours)
  • Area under the curve of glucose levels below 3.3 mmol/L(120 hours)
  • Area under the curve of glucose levels below 2.8 mmol/L(120 hours)
  • Percentage of time of glucose levels spent between 3.9 and 7.8 mmol/L(120 hours)
  • Percentage of time of glucose levels spent below 3.9 mmol/L(120 hours)
  • Percentage of time of glucose levels spent below 3.3 mmol/L(120 hours)
  • Percentage of time of glucose levels spent below 2.8 mmol/L(120 hours)
  • Percentage of time of glucose levels spent above 10 mmol/L(120 hours)
  • Percentage of time of glucose levels spent above 13.9 mmol/L(120 hours)
  • Percentage of time of glucose levels spent above 16.7 mmol/L(120 hours)
  • Percentage of time of overnight glucose levels spent between 3.9 and 10.0 mmol/L(35 hours)
  • Percentage of time of overnight glucose levels spent below 3.3 mmol/L(35 hours)
  • Percentage of time of overnight glucose levels spent below 3.9 mmol/L(35 hours)
  • Percentage of time of overnight glucose levels spent between 3.9 and 7.8 mmol/L(35 hours)
  • Area under the curve of glucose levels above 10 mmol/L(120 hours)
  • Area under the curve of glucose levels above 13.9 mmol/L(120 hours)
  • Area under the curve of glucose levels above 16.7 mmol/L(120 hours)
  • Area under the curve of overnight glucose levels below 3.9 mmol/L(35 hours)
  • Area under the curve of overnight glucose levels below 3.3 mmol/L(35 hours)
  • Area under the curve of overnight glucose levels below 2.8 mmol/L(35 hours)
  • Area under the curve of overnight glucose levels above 10 mmol/L(35 hours)
  • Area under the curve of overnight glucose levels above 13.9 mmol/L(35 hours)
  • Area under the curve of overnight glucose levels above 16.7 mmol/L(35 hours)
  • Mean glucose levels(120 hours)
  • Standard deviation of glucose levels(120 hours)
  • Standard deviation of insulin delivery(120 hours)
  • Coefficient of variance of glucose levels(120 hours)
  • Coefficient of variance of insulin delivery(120 hours)
  • Between-day variability in glucose levels(120 hours)
  • Between-day variability in insulin delivery(120 hours)
  • Total insulin delivery(120 hours)
  • Percentage of time of closed-loop operation(120 hours)
  • Percentage of time of glucose sensor availability(120 hours)
  • Time between failures(120 hours)
  • Number of hypoglycemic events less than 3.1 mmol/L(120 hours)
  • Number of nights with hypoglycemic events less than 3.1 mmol/L(35 hours)
  • Number of days with hypoglycemic events less than 3.1 mmol/L(120 hours)

研究者

发起方
Institut de Recherches Cliniques de Montreal
申办方类型
Other
责任方
Principal Investigator
主要研究者

Rémi Rabasa-Lhoret

Associate Professor of Medicine

Institut de Recherches Cliniques de Montreal

研究点 (1)

Loading locations...

相似试验