跳至主要内容
临床试验/NCT06176170
NCT06176170进行中(未招募)不适用

A Prospective Multicentre Pivotal Clinical Study to Demonstrate the Efficacy and Safety of the VividWhite Glaucoma Implant (VW-51) for the Treatment of Glaucoma.

VividWhite Pty Ltd12 个研究点 分布在 1 个国家目标入组 65 人开始时间: 2023年12月12日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
进行中(未招募)
发起方
入组人数
65
试验地点
12
主要终点
Complete success by efficacy and safety criteria

研究概览

简要总结

The VividWhite Glaucoma Implant (VW-51) is a novel surgical implant designed to treat glaucoma. This study is a 12-month, 65-participant non-comparative multicentre study to assess the safety and effectiveness of the VW-51 implant.

详细描述

A prospective multicentre non-comparative pivotal clinical study where all participants undergo treatment with a novel surgical implant (VW-51) and receive 12 months of clinical follow-up. The study aim is to assess the effectiveness, safety and participant experience of the VW-51 implant for the treatment of glaucoma. The study population will involve 65 adult participants with medically or surgically refractory glaucoma. The VW-51 implant is a leaf-shaped microfluidic device manufactured from flexible silicone, designed to be surgically implanted in the subconjunctival space, drain aqueous humor from the eye and reduce intraocular pressure to treat glaucoma.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Glaucoma in the study eye, meeting the following requirements:
  • •Glaucoma is diagnosed by the investigator based upon untreated intraocular pressure, disc appearance and visual field abnormalities, and where the disease type is one of: Primary open angle glaucoma (POAG); Chronic angle closure glaucoma (CACG) where the eye is pseudophakic and a laser iridotomy has previously been performed; Pigmentary open angle glaucoma; Exfoliation open angle glaucoma; Rubeotic glaucoma that is treated and regressed/quiescent; Steroid-induced glaucoma; or Juvenile open angle glaucoma (JOAG).
  • •There has been failure of previous treatment for glaucoma (it is 'refractory'), meeting ONE of the following requirements:
  • •i. Failure of medical treatment: inadequate IOP control on maximum tolerated medical therapy.
  • •ii. Failure of previous glaucoma surgery (not more than one operation) with trabeculectomy, Xen/PreserFlo, non-penetrating glaucoma surgery, a previously removed suprachoroidal drainage device, trabecular bypass (using iStents or Hydrus), or cilioablation.
  • •c. The mean diurnal IOP at Screening/Baseline is ≥ 20 mmHg, and ≤ 40 mmHg.
  • •d. The conjunctiva in the target quadrant is healthy, mobile and suitable for glaucoma surgery.

排除标准

  • •in the study eye:
  • •Advanced glaucomatous optic neuropathy that threatens fixation, in the opinion of the investigator.
  • •The glaucoma type is any of the following: Acute Angle Closure Glaucoma (AACG); Chronic Angle Closure Glaucoma where the eye is phakic; Congenital glaucoma; or Secondary glaucoma of any type not specified in the inclusion criteria, including inflammatory glaucoma, active neovascular/rubeotic glaucoma, traumatic glaucoma, Iridocorneal Endothelial (ICE) Syndrome, and silicone oil induced glaucoma.
  • •Previous glaucoma surgery with: a tube-and-plate glaucoma drainage device (GDD, e.g. Molteno, Baerveldt, Ahmed, Schocket); an in-situ suprachoroidal implant; or multiple previous operations for glaucoma.
  • •Cataract surgery or any other ocular surgery is indicated at the time of study intervention or is anticipated to be required during the study duration.
  • •Central corneal endothelial cell density less than specified age-related thresholds at screening.
  • •Intraocular silicone oil.
  • •Significant corneal, retinal, inflammatory or infective ophthalmic pathology (full details specified in the protocol).

研究组 & 干预措施

VividWhite Glaucoma Implant (VW-51)

Experimental

Surgical implantation of VW-51.

干预措施: VividWhite Glaucoma Implant (VW-51) (Device)

结局指标

主要结局

Complete success by efficacy and safety criteria

时间窗: Study completion (12 months)

Efficacy Criteria: 1. Intraocular pressure (IOP) is less than or equal to 21 mmHg. 2. IOP is reduced by greater than or equal to 20% compared to baseline (mean diurnal). 3. Treatment with the same number or fewer classes of topical glaucoma medication than at baseline. 4. No requirement for: further glaucoma surgery indicated for efficacy (at any time during the study); or systemic/oral ocular hypotensive medication to achieve target IOP in the study eye (at any time during the study). Safety Criteria: 5. IOP is greater than or equal to 6 mmHg. 6. No adverse events of special significance in the study eye (as specified by the protocol; for example further glaucoma surgery indicated for safety).

次要结局

未报告次要终点

研究者

发起方
VividWhite Pty Ltd
申办方类型
Industry
责任方
Sponsor

研究点 (12)

Loading locations...

相似试验