The Effect of Surface Treatment of the Dental Implant on the Osseointegration in Mandibular Posterior Missing Teeth

Hams Hamed Abdelrahman1 个研究点 分布在 1 个国家目标入组 16 人开始时间: 2020年11月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
16
试验地点
1
主要终点
Change in implant stability

研究概览

简要总结

Dental implants have become a widely accepted treatment modality for the replacement of missing single or multiple teeth in the recent years. In order to meet patients' needs for shorter treatment times and the necessity of dealing with more challenging clinical situations, implants and implant therapies have undergone continuous improvement to improve the function and longevity of the implants. Recently the constant search for improvements in modern implant have been focused on surface modifications so a new era of surface treatment have been showed up; the chemically modified hydrophilic surfaces.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
20 Years 至 40 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • Missing mandibular posterior teeth.
  • Good oral hygiene (plaque index less than 10 %)
  • Good compliance to the treatment.
  • Participants are free from local or systemic disease
  • Willingness and ability to commit to follow-up placement.
  • Adequate bone height and width to accommodate implant placement and sufficient keratinzed mucosa.
  • At least 3months after tooth extraction
  • Sufficient interocclusal distance
  • Exclusion criteria
  • Presence of persistent and unresolved infection in the implant site
  • Parafunctional habits.
  • Heavy Smokers.
  • Uncontrolled systemic disease that impedes bone healing

排除标准

  • 未提供

结局指标

主要结局

Change in implant stability

时间窗: at baseline and 6 months

The implant stability measurement was examined at the time of insertion of the implants (primary stability) and 6 months (secondary stability) for the two groups of patients using the resonance Frequency Analysis (RFA) via the Osstell ISQ system

Biochemical assessment of bone formation

时间窗: at 3 months

Done by measuring of Runt-related transcription factor 2 (RUNX2) as a bone marker by Enzyme-Linked Immunosorbent Assay

Change in bone density

时间窗: at baseline and 6 months

Cone beam Computerized tomography was used to assess bone denisty

Change in ridge height

时间窗: at baseline and 6 months

Cone beam Computerized tomography was used to assess ridge height