Establishing a Non-invasive Method to Measure Heart Performance

Marie Csete MD, PhD2 个研究点 分布在 1 个国家目标入组 72 人开始时间: 2014年8月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
72
试验地点
2
主要终点
Magnetic resonance measures of cardiac function

研究概览

简要总结

The purpose of the study is to evaluate a new way to examine cardiac function, using software developed at Caltech. The experimental device is software loaded on an iPhone. The iPhone is used to capture a pulse (waveform) by simply placing the iPhone lightly over the neck where the carotid pulse can be felt. In this study the information collected from the iPhone app is compared to cardiac function data obtained from the current gold standard for measuring cardiac function, cardiac magnetic resonance imaging (MRI). Subjects referred from cardiologists will also generally have echocardiography information available for comparison with the iPhone app. For the study, subjects will have completely non-invasive studies done in one setting: The iPhone app to capture the waveforms (over carotid and radial (wrist) arteries), tonometry (another non-invasive method using a modified stethoscope), standard pulse oximetry, followed by a 30 minute MRI examination of the heart. A second complete study will be done about 6 months after the first. The complete study session takes about 1.5 hours.

详细描述

Investigators at Caltech have developed an iPhone-based application that allows them to capture an arterial waveform using the iPhone camera held over the skin. Then based on the captured waveform and previous laboratory experiments and models, the investigators are able to calculate ejection fraction, the percentage of blood that goes out of the heart into the circulation with each beat. Previous studies suggested that the iPhone app measurements of ejection fraction were similar to those obtained with traditional cardiac echocardiography. In the current study the iPhone app measures are being compared to ejection fraction obtained using cardiac MRI. The iPhone also measures other physical properties of the heart and aorta that the investigators call "intrinsic frequencies". Using healthy subjects they have established the normal pattern/range of intrinsic frequencies, and in this study, a more diverse population of subjects (some with heart disease) will be studied, to determine how intrinsic frequency measures compare to traditional clinical measures of cardiac function.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adult age 18-90, outpatients

排除标准

  • Inability to lie flat for 30 minutes with periodic breath holding
  • Metal implants or other standard contraindications to MRI
  • Acute cardiac decompensation (active chest pain, shortness of breath)
  • Hypotension (SBP<90 mm Hg)
  • Claustrophobia
  • Patient too large to fit in closed MRI

结局指标

主要结局

Magnetic resonance measures of cardiac function

时间窗: Within 1 month of study

Standard end-points of cardiac function such as chamber size and relaxation.

次要结局

未报告次要终点

研究者

发起方
Marie Csete MD, PhD
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Marie Csete MD, PhD

Chief Scientific Officer

Huntington Medical Research Institutes