Feasibility Study DK150OS. Testing of Compression Textile. A Safety Study Among Healthy Volonteers
试验速览
- 阶段
- 不适用
- 状态
- 终止
- 入组人数
- 11
- 主要终点
- Intra Abdominal Pressure (IAP)
研究概览
简要总结
This safety study was carried out to investigate to what extent the use of an abdominal binder influences IAP. The study was designed as a comparative cross-over study measuring bladder pressure.
详细描述
Study Description: Transabdominal surgery might be associated with incisional pain, fear of rupture, inhibited mobilisation and risk of incisional herniation. An abdominal binder was developed for postoperative support of abdominal incisions. The abdominal binder provides a pressure of 10-15 mmHg.
Worlds Society on Abdominal Compartment Syndrome (WSACS) defines that Normal Intra-Abdominal Pressure (IAP) is approximately 5-7 mmHg in critically ill adults, and that Intra-Abdominal Hypertension (IAH) is a sustained or repeated pathologic elevation of IAP >12 mmHg. This safety study was carried out to investigate to what extent the use of the abdominal binder influences IAP. The study was designed as a comparative cross-over study measuring bladder pressure (Foley manometer, Holtec Medical, Copenhagen) in 11 healthy volunteers with and without wearing the abdominal binder.
Results IAP measurements without wearing the abdominal binder were found to be surprisingly high with a range between 8,0 and 16,7 mmHg. (mean 10,5 mmHg.). This finding is explained by the fact that the subjects were not under relaxation and the fact that half of the subjects according to their BMI were categorised as being overweight or fat. Other investigations have demonstrated that relaxation decreases IAP and that BMI is positively related to IAP.
We found that wearing the abdominal binder did increase IAP with a mean of 4,0 mmHg. (+/-1,4) or 39,3% (+/-14,61%).
In conclusion Relating our results to the WSACS guidelines regarding IAP and IAH it is not likely that the use of the abdominal binder will increase IAP to a clinically critical extent in patients with normal IAP. It must though be assessed from case to case, whether the use of the abdominal binder is appropriate.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Minimum 18 years old
- •Negative test of blood, nitrate or leucocytes in urinre
- •Waist line measurement 97-110 cm
排除标准
- •Known allergy
- •Know bladder disease
- •Tendency of/clinicla symptoms of urinay infection
- •Abdominal or urinary surgery
- •Medical treatment
结局指标
主要结局
Intra Abdominal Pressure (IAP)
Mean Arterial Pressure (MAP)
Abdominal Perfussion Pressure (APP)
次要结局
- Comfort
- Freedom of movement
