跳至主要内容
临床试验/NCT04510363
NCT04510363招募中不适用

Optic Nerve Sheath Diameter, Carotid Duplex and Transcranial Duplex as a Prognostic Predicting Factor in Post-cardiac Arrest Patients

National Taiwan University Hospital1 个研究点 分布在 1 个国家目标入组 200 人开始时间: 2019年12月17日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
200
试验地点
1
主要终点
optic nerve sheath diameter (ONSD)

研究概览

简要总结

Optic nerve sheath diameter (ONSD) had been proved to be associated with increased intracranial pressure and can be used as one of the prognostic factors in cardiac arrest patients. It is simple, quick and can be measured repeatedly. Carotid duplex and transcranial duplex(TCD) provide rapid, noninvasive, real-time measures of cerebrovascular function. It can be used to assess the vascular territory by measuring blood flow, and to evaluate factors include brain perfusion, plaque morphology, and patency of intracranial collaterals. Hence, it could act as a crucial role in neuroprognosis in post-arrest patients. In this study, the investigator aimed to analyze the ONSD diameters, ONSD/external transverse diameter (ETD) ratio, carotid duplex and transcaranial duplex parameters in different stages of post-cardiac arrest care, demographic characteristics and resuscitation information with the neurological outcome of post-cardiac arrest patients. The ONSD diameter, and ONSD/ETD ratio were compared with age-, and sex-matched normal volunteers.

详细描述

Prediction of the neurological outcome in resuscitated post-cardiac arrest patients is important to tailor appropriate management plans. Brain imaging, electrophysiological evaluations, biomarkers all take part in neuroprognosis in cardiac arrest patients, however, these modalities are more expensive or not suitable to repeat in a short time. Optic nerve sheath diameter (ONSD) had been proved to be associated with increased intracranial pressure2 and can be used as one of the prognostic factors in cardiac arrest patients. It is simple, quick and can be measured repeatedly. Carotid duplex and transcranial duplex(TCD) provide rapid, noninvasive, real-time measures of cerebrovascular function. It can be used to assess the vascular territory by measuring blood flow, and to evaluate factors include brain perfusion, plaque morphology, and patency of intracranial collaterals.

Hence, it could act as a crucial role in neuroprognosis in post-arrest patients. In this study, the investigator aimed to analyze the ONSD diameters, ONSD/ETD ratio, carotid duplex and transcaranial duplex parameters in different stages of post-cardiac arrest care, demographic characteristics and resuscitation information with the neurological outcome of post-cardiac arrest patients.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Prospective

入排标准

年龄范围
20 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • . Non-traumatic cardiac arrest adult patients achieving return of spontaneous circulation after resuscitation

排除标准

  • traumatic cardiac arrests
  • non-traumatic arrest patients without return of spontaneous circulation after resuscitation

结局指标

主要结局

optic nerve sheath diameter (ONSD)

时间窗: 7 days

ONSD measured by ultrasonography during the post-arrest care

carotid artery resistance

时间窗: 7 days

carotid artery resistance measured by ultrasonography during the post-arrest care

middle cerebral artery resistance

时间窗: 7 days

middle cerebral artery resistance measured by ultrasonography during the post-arrest care

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...