Determination of Quantitative Beta-hCG Levels in Patients Through Alternative and Less Invasive Sample Types

Simple HealthKit1 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2022年10月11日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
40
试验地点
1
主要终点
Correlation of matched serum and DBS samples for detection of beta hCG levels using an ECL analyzer.

研究概览

简要总结

This study is to determine if there is any quantifiable correlation between serum beta hCG and dried blood spot (DBS) beta hCG levels. This data will be used to develop a less invasive collection method to determine quantitative hCG levels.

详细描述

A cohort of 40 individuals at various stages of pregnancy or medical abortion will be recruited for the study. Each participant will provide biospecimens that include the following: serum, saliva, urine, and dried blood spot (DBS). These samples will be collected and stored at the clinic under appropriate storage conditions until they can be shipped, under dry ice, to the testing lab. Once samples arrive at the lab, serum samples will be thawed and prepared to run on an ECL analyzer to determine reference beta hCG values in mIU/mL for each participant.

Samples will be run as they are received by the lab. The initial 10-12 samples will be used to evaluate study feasiblility and determine if there is one sample type that performs better than the others. The other matched sample types will be processed and run on the ECL analyzer. The values for beta hCG mIU/mL of the other sample types will then be compared to the matched serum to determine if there are any consistent correlations.

In the first 10-12 samples, if one sample type is shown to perform better than the others, the study will shift focus towards prioritizing the analysis of that particular sample type in regards to correlation with serum. If more than one sample type is shown to perform well, then those sample types will be equally prioritized. If no sample type shows any correlation, the study will end.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • Are at least 18 years old
  • Have not taken antibiotics in the last 21 days
  • Are here for services related to a current or recent pregnancy
  • Agree to provide all required samples
  • Have not previously participated in this study

排除标准

  • Are under18 years old
  • Have taken antibiotics in the last 21 days
  • Are not here for services related to a current or recent pregnancy
  • Disagree or unable to provide all required samples
  • Have previously participated in this study

结局指标

主要结局

Correlation of matched serum and DBS samples for detection of beta hCG levels using an ECL analyzer.

时间窗: 2-24 hours

It was determine that serum and DBS samples show a consistent correlation. DBS beta hCG levels can be converted to reflect those of serum beta hCG. By utilization of a dilution factor, DBS beta hCG levels matched that of serum beta hCG levels with an average accuracy of 94.8%. Serum samples were run on an analyzer to obtain reference values in mIU/mL. Dried blood spot (DBS) samples, that were matched for both time of collection and patient, were extracted with an elution buffer coupled with agitation. This eluate was run on the same analyzer as the serum samples and the resulting beta hCG levels in mIU/mL were corrected with a dilution factor and compared to the serum reference values.

次要结局