跳至主要内容
临床试验/NCT06186765
NCT06186765进行中(未招募)不适用

Prospective, Non-randomized, Multicenter Clinical Evaluation of the Recharge Free Axonics SNM System (Model 4101)

Axonics, Inc.16 个研究点 分布在 3 个国家目标入组 144 人开始时间: 2023年12月8日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
进行中(未招募)
发起方
Axonics, Inc.
入组人数
144
试验地点
16
主要终点
Performance/Effectiveness - Improvement in Quality of Life scoring (OAB)

研究概览

简要总结

Multicenter, prospective, non randomized, single arm evaluation of patients with overactive bladder (OAB) and/or fecal incontinence (FI) employing the Axonics recharge free SNM System.

详细描述

A clinical evaluation to comply with new European Medical Device Regulations (EU MDR) guidelines. Multicenter, prospective, non-randomized, single arm study for OAB and/or FI to assess the safety and performance of the Food and Drug Administration (FDA) approved Axonics recharge free sacral neuromodulation (SNM) System, INS Model 4101. The product is currently marketed under the name F15.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 18 years or older
  • Primary indication of overactive bladder (OAB) (urinary urgency incontinence (UUI)/ urinary frequency (UF)) or fecal incontinence (FI) who are not candidates for, or who have failed conservative treatment
  • Willing and capable to provide written informed consent and agrees to comply with specified evaluations at clinical investigational sites and attend all follow-up assessments for up to 1 year.

排除标准

  • Any significant medical condition that is likely to interfere with procedures, device operation, or likely to confound evaluation of endpoints (exclusion of neurological conditions such as multiple sclerosis)
  • Any psychiatric or personality disorder that is likely to interfere with procedures at the discretion of the participating physician; this may include poor understanding or compliance with requirements
  • Previously underwent an external sacral neuromodulation (SNM) trial and was deemed a non-responder or was previously implanted with a sacral neuromodulation device and did not get therapeutic benefit (a non-responder)
  • History of allergic response to titanium, zirconia, polyurethane, epoxy, or silicone
  • A female who is breastfeeding
  • A female with a positive urine pregnancy test

研究组 & 干预措施

Single Arm - Treatment Groups separated into OAB and FI

Other

Treatment Arm separated into 2 cohorts:

  1. Overactive Bladder (OAB)
  2. Fecal incontinence (FI)

干预措施: Axonics SNM System (Model 4101) (Device)

结局指标

主要结局

Performance/Effectiveness - Improvement in Quality of Life scoring (OAB)

时间窗: 3 months

International Consultation on Incontinence Questionnaire Overactive Bladder Quality of Life (ICIQ-OABqol): questions in each subscale are scored by a summed range of 0 to 100, with a higher score indicating better quality of life. Overall score ≥ 10 points from baseline to follow-up is indicative of a clinically meaningful improvement.

Performance/Effectiveness - Improvement in Fecal Incontinence Survey

时间窗: 3 months

Cleveland Clinic Florida - Fecal Incontinence Score (CCF-FIS): includes 5 items (solid, liquid, gas, wears pad and lifestyle alteration) and 5 frequencies (never = 0, rarely = 1, sometimes = 2, usually = 3, always = 4). Scores range from 0 for full continence to 20 for complete incontinence. A higher score is indicative of the severity of fecal incontinence.

Adverse event reporting (Safety)

时间窗: 3 months

Device-related, procedure-related and all serious adverse events

Performance/Effectiveness - Improvement in Quality of Life scoring (OAB)

时间窗: 3 months

International Consultation on Incontinence Questionnaire Overactive Bladder Quality of Life (ICIQ-OABqol): questions in each subscale are scored by a summed range of 0 to 100, with a higher score indicating better quality of life. Overall score ≥ 10 points from baseline to follow-up is indicative of a clinically meaningful improvement.

Performance/Effectiveness - Improvement in Fecal Incontinence Survey

时间窗: 3 months

Cleveland Clinic Florida - Fecal Incontinence Score (CCF-FIS): includes 5 items (solid, liquid, gas, wears pad and lifestyle alteration) and 5 frequencies (never = 0, rarely = 1, sometimes = 2, usually = 3, always = 4). Scores range from 0 for full continence to 20 for complete incontinence. A higher score is indicative of the severity of fecal incontinence.

Adverse event reporting (Safety)

时间窗: 3 months

Device-related, procedure-related and all serious adverse events

次要结局

  • Performance/Effectiveness - Improvement in Quality of Life scoring (OAB)(1 year)
  • Performance/Effectiveness - Improvement in Fecal Incontinence Survey(1 year)
  • Adverse event reporting (Safety)(1 year)
  • Performance/Effectiveness - Improvement in Quality of Life scoring (OAB)(1 year)
  • Adverse event reporting (Safety)(1 year)
  • Performance/Effectiveness - Improvement in Fecal Incontinence Survey(1 year)
  • Performance/Effectiveness - Improvement in Quality of Life Survey (FI)(3 months, 6 months, 1 year)

研究者

发起方
Axonics, Inc.
申办方类型
Industry
责任方
Sponsor

研究点 (16)

Loading locations...

相似试验