Interest of High-speed Centrifugation for Measuring Anti-Xa Activity on Lipemic Plasma
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 发起方
- 入组人数
- 150
- 试验地点
- 1
- 主要终点
- To determine whether high-speed centrifugation (10,800g for 10 minutes) effectively separates the lipid fraction from the rest of the plasma
研究概览
简要总结
Some hemostasis techniques require spectrophotometric measurements. These are then subject to interference from the sample's lipemia (postprandial, hypertriglyceridemia, etc.), which risks distorting the results; this is estimated to affect 0.5 to 2.5% of samples.
This is particularly the case for anti-Xa activity, a critical test used to monitor anticoagulant treatments.
To date, the HUS Hematology Laboratory does not have or is aware of any alternative method to overcome this interference, and is unable to perform anti-Xa activity when the sample has excessive lipemia. This study will evaluate, on samples from routine care artificially overloaded with lipids, the effectiveness of a high-speed centrifugation process (10,800g for 10 minutes).
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Adult patient (≥ 18 years)
- •Patient anticoagulated with an anti-Xa (UFH, LMWH, fondaparinux, danaparoid, apixaban, rivaroxaban)
- •Sample sent to the HUS Hematology Laboratory and analyzed for measurement of the anti-Xa activity of an anticoagulant as part of routine care
排除标准
- •Patient with a basal lipidemic sample
- •Sample of insufficient volume
结局指标
主要结局
To determine whether high-speed centrifugation (10,800g for 10 minutes) effectively separates the lipid fraction from the rest of the plasma
时间窗: Up to 10 minutes
To determine whether high-speed centrifugation (10,800g for 10 minutes) effectively separates the lipid fraction from the rest of the plasma, in order to measure anti-Xa activity, and to ensure that this process does not interfere with this measurement.
次要结局
未报告次要终点