跳至主要内容
临床试验/NCT01723865
NCT01723865已完成不适用

Clinical Efficacy of a Specifically Dedicated Remote Monitoring System in the Management of Patients With Heart Failure and ICD&CRT-D.

Effect Group, Italy16 个研究点 分布在 1 个国家目标入组 988 人开始时间: 2011年5月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
988
试验地点
16
主要终点
unplanned hospitalizations or death

研究概览

简要总结

This is a clinical trial to evaluate the clinical benefit of remote monitoring in patients with heart failure having an ICD-CRT implanted.

Study purpose The purpose of this study is to test the hypothesis that the monitoring of specific clinical parameters, obtained by remote controls of ICD-CRT could improve clinical course of patients with heart failure.

Study design This is a prospective observational study, comparing clinical course of patients with heart failure having an ICD-CRT implanted, followed or not by remote monitoring. This study will include 870 subjects with ICD and CRT-D, and followed by a remote monitoring system (with or without weight and pressure external sensors) or followed by conventional ambulatory visits.

Primary endpoints The primary endpoint of this study is to document no superiority of unplanned hospital access for cardiac reasons (included access to the emergency units ) or death for cardiovascular causes in remote monitoring group (with or without weight and pressure external sensors) compared to conventional follow-up (usual care group).

详细描述

Aim of the study The purpose of this study is to evaluate the clinical benefit of a dedicated remote monitoring system (RPM) in the management of patients with heart failure and implanted with ICDs and CRT-D.

The clinical benefit will be assessed by:

  • Increased cardiovascular events (death, myocardial infarction, hospitalization).
  • Events arrhythmia: atrial fibrillation, sustained and nonsustained ventricular tachycardia or ventricular fibrillation.
  • Autonomic profile, echocardiographic parameters, 6-minute walk test, quality of life questionnaire.

The primary endpoint of this study is to estimate the incidence (and its accuracy) of the first event of unplanned hospitalizations for cardiac reasons or death from cardiovascular causes in the group monitored using RPM (with or without external sensors) and in the group management via conventional follow-up (Usual Care).

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Subjects >18 years
  • patients implanted or eligible for implant with ICD-CRT-D, accordingly with guidelines of the centers, for heart failure treatment and/or primary prevention of sudden death

排除标准

  • Presence of clinically overt heart failure.
  • Myocardial infarction within 2 months before enrolment.
  • Significant concurrent illness or condition severely limiting life expectancy.
  • Any surgical or medical condition which, at the discretion of the investigator, place the patient at higher risk from his/her participation in the study, or are likely to prevent the patient from complying with the requirements of the study or completing the trial period.
  • History of drug or alcohol abuse within the last 2 years.
  • Inability to communicate and comply with all study requirements including the unwillingness or inability to provide informed consent.

结局指标

主要结局

unplanned hospitalizations or death

时间窗: 1 year

unplanned hospitalization or for cardiac reasons or death for cardiovascular causes in the group monitored using RPM (with or without external sensors) and in the group management via conventional follow-up (Usual Care).

次要结局

  • All reasons hospitalizations(1 year)
  • Hospitalization for cardiac causes(1 year)
  • Myocardial infarction(1 year)
  • Atrial fibrillation(1 year)
  • Heart transplantation(1 year)
  • Cost for National Health System (NHS)(1 year)
  • Ventricular tachycardia or fibrillation(1 year)
  • Clinical benefit(1 year)

研究者

发起方
Effect Group, Italy
申办方类型
Network
责任方
Sponsor

研究点 (16)

Loading locations...

相似试验

Clinical Efficacy of Remote Monitoring in the... | 临床试验