Auto Control of Volume Management for Limb Loss

University of Washington2 个研究点 分布在 1 个国家目标入组 104 人开始时间: 2015年8月7日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
104
试验地点
2
主要终点
Change in Limb Volume

研究概览

简要总结

The aim of this research is to create a prosthetic system that will automatically adjust the fit of the socket and create a well-fitting prosthesis for people with leg amputations who experience volume fluctuations when using their prosthesis.

详细描述

People with lower limb amputations often experience daily changes in the size (volume) of their residual limb. These daily changes can cause a prosthesis to fit poorly. They can also cause limb health problems including skin breakdown and injury to deeper tissues. Prosthetic socket systems that accommodate limb volume changes can help address these issues, but they require users to make adjustments throughout the day.

The objective of this research is to develop and test an automatically-adjusting prosthetic socket system for prosthesis users. The system integrates with a range of adjustable socket technologies, including those that are commercially available. The system allows small size adjustments for both tightening and loosening the socket. In early aims of the study, the prosthesis will be adjusted manually, but can be controlled remotely, eliminating the need to remove the prosthesis or bend down to make adjustments. The system will later be enhanced to automatically change the fit of an adjustable socket at the appropriate times, without distracting the user. We hypothesize that this system will help to maintain consistent limb fluid volume while the prosthesis user is wearing the socket and that socket fit will be improved. The system functions by continuously collecting measurements from sensors within the socket and uses small motors to control adjustable panels in the socket wall.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Single Group
主要目的
Supportive Care
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 18 years of age or older
  • Unilateral transtibial amputee
  • At least 6 months post-amputation
  • Wear prosthesis at least 3 hours per day
  • Use an elastomeric (i.e. gel) liner
  • K3 or higher Medicare Functional Classification Level
  • Able to walk continuously with prosthesis for at least 5 minutes at a time, sit, stand, and step up a height of 5.0 cm.
  • Residual limb of 9.0 cm or longer
  • Experience problems with volume fluctuations that affect their prosthetic socket fit

排除标准

  • Participants experiencing skin breakdown on enrollment will be excluded, but can enter after having been free of clinically visually-apparent skin breakdown for two weeks.

结局指标

主要结局

Change in Limb Volume

时间窗: Change from baseline period (non-adjustment) to test period (adjustment), commonly each 1 hour long and separated by a seated period of approximately 30 minutes.

Limb volume fluctuations will be measured in real-time as socket adjustment strategies are tested. This will be accomplished using a portable bioimpedance device with thin sticky electrodes that are placed on the residual limb. Specifically, the change in limb volume will be assessed from a baseline period where no socket adjustments are made to another period within the same test session where socket adjustments are made.

Change in Limb Movement

时间窗: Change from baseline period (non-adjustment) to test period (adjustment), commonly each 1 hour long and separated by a seated period of approximately 30 minutes.

Limb movement within the socket will be measured as socket adjustment strategies are tested. It will be used as an indicator of how well the socket is fitting (loose, tight, etc). The measurement will be made using an inductance sensor that is placed in the socket which measures the displacement of a sensor patch on the prosthetic liner. Specifically, the change in limb movement will be assessed from a baseline period where no socket adjustments are made to another period within the same test session where socket adjustments are made.

Number of Participants With Increase in Limb Fluid Volume After Panel Pull

时间窗: Change from baseline period (non-adjustment) to test period (adjustment), commonly each 1 hour long and separated by a seated period of approximately 30 minutes.

Limb volume fluctuations will be measured in real-time as socket adjustment strategies are tested. This will be accomplished using a portable bioimpedance device with thin sticky electrodes that are placed on the residual limb. Specifically, the change in limb volume will be assessed from a baseline period where no socket adjustments are made to another period within the same test session where socket adjustments are made.

Integral of Absolute Error to Maintain Set Point

时间窗: Over 30 minutes of controlled use of the auto-adjusting socket

Clinically acceptable socket volume error as measured by an automatically adjusting prosthetic socket attempting to maintain a set socket volume set point, based on sensed distance (measured in mm).