A Performance Evaluation of the LumiraDx Point Of Care D-dimer Assay
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 679
- 试验地点
- 14
- 主要终点
- Determine the accuracy of the LumiraDx POC D-Dimer assay when compared to a reference method in patients with suspected VTE.
研究概览
简要总结
In patients with symptoms of Venous Thromboembolism (VTE) (mainly deep vein thrombosis (DVT) or pulmonary embolism (PE)), the study will evaluate the agreement between the D-Dimer measurements from the LumiraDx POC D-Dimer assay and a reference method, as an aid in diagnosis, assessment and exclusion of DVT and PE.
详细描述
This is a performance evaluation study designed to assess the precision and accuracy of the LumiraDx Point of Care (POC) D-Dimer test when used in patients presenting with symptoms of Venous thromboembolism (VTE), which mainly comprises deep vein thrombosis (DVT) or pulmonary embolism (PE).
The LumiraDx POC D-Dimer test is a quantitative immunoassay providing results in under 10 minutes. The accuracy of the LumiraDx POC D-Dimer test will be assessed using capillary whole blood, venous blood, and plasma samples, by comparison to the D-Dimer results obtained from the same individuals as analysed by trained laboratory professionals using a reference device. The results of this study are intended to be used for regulatory filings for use as an in vitro diagnostic test in the European Union (EU) and other relevant geographies.
Adult males and females presenting to the study sites with symptoms of VTE will be included in the study. Approximately 1000 subjects will be recruited in total. An initial analysis will be completed on the first 200 patients to determine accuracy of the LumiraDx D-Dimer test versus the reference method. The study will continue until 1000 patients are recruited and with a minimum of 120 confirmed VTE events, in order to complete retrospective analysis using the LumiraDx D-Dimer cut-off for exclusion of VTE.
Once consent is obtained, blood tube samples will be drawn and finger-stick samples of capillary blood will be taken from the subject, these will be applied directly to unique test strips for immediate measurement of D-Dimer on the LumiraDx POC D-Dimer test.
The D-Dimer results obtained via the LumiraDx D-Dimer test will be used in a set of comparative analyses designed to determine the performance characteristics of the test. This study is an observational, cross-sectional design. As an observational study of an investigative device, results obtained during the course of the study will not inform or alter patient management or treatment decisions in any way.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Subject is greater or equal to 18 years of age Willing and able to provide written informed consent and comply with study procedures Symptoms of thromboembolic event
排除标准
- •Suspected Sinus Venous Thromboembolism / Cerebral Venous Sinus Thromboembolism End-stage renal failure on haemodialysis Current anticoagulant therapy (Fragmin, LMWH) within the last 30 days Patient has previously participated in this study Life expectancy documented as <30 days Haemodynamically unstable (e.g. cardiogenic shock) Patients taking anticoagulant therapy (DOACS, Warfarin, Heparins etc) within the last 30 days Patient deemed medically unfit to participate
研究组 & 干预措施
Suspected VTE patients
Venous blood draw of up to 20ML and up to 6 fingerstick capillary draws
干预措施: Venepuncture (Diagnostic Test)
Suspected VTE patients
Venous blood draw of up to 20ML and up to 6 fingerstick capillary draws
干预措施: Fingerstick (Diagnostic Test)
结局指标
主要结局
Determine the accuracy of the LumiraDx POC D-Dimer assay when compared to a reference method in patients with suspected VTE.
时间窗: 2 months
Measurement of blood samples from patients with suspected VTE in a reference method and in the LumiraDx method to assess accuracy of the LumiraDx method.
Assessment of accuracy of using the D-Dimer cut-off set by the LumiraDx D-Dimer test in excluding patients with symptoms of VTE (DVT and PE) when used in combination with the pre-probability test (Wells Score).
时间窗: 10 months
Measurement of blood samples from patients with suspected VTE in the LumiraDx D-dimer assay in conjunction with pre-test probability score and final clinical outcome in order to set a clinical cut-off for the LumiraDx D-dimer assay