简要总结

Worldwide, in terms of attributable deaths, the main intermediate risk factor for the development of cardiovascular diseases is systemic arterial hypertension, followed by overweight and sustained hyperglycemia. These factors have positively influenced public and private spending on health. The more robust studies showed that age is one of the main determinants of arterial stiffness. However, there is a possibility that other variables, such as elevated glucose levels, obesity, and systemic inflammation itself, as well as insulin resistance are important factors in this scenario. On the other hand, the measurement of the pulse wave velocity is widely acceptable for the evaluation of the arterial stiffness, inferring the cardiovascular risk in different populations. Since arterial stiffness is influenced by hemodynamic forces and inflammatory mediators, which may be related to sodium and glucose balance, it is necessary to evaluate whether a hypocaloric and low glycemic load diet, in a thesis that decreases lipid and inflammatory levels, may have favorable effects on pulse wave velocity in overweight adults.

详细描述

The diets will be calculated in Microsoft Excel 2018 software, using tables of nutritional composition, glycemic index and glycemic load, which have foods with high glycemic index or glycemic load (white rice, white bread, corn flakes, mashed potatoes, orange juice (brown rice, whole wheat bread, whole noodles, oat bran, yogurt, milk, apple, pear, peach). The methodology for calculating GC estimates will be based on the FAO / WHO Protocol. The diets will be designed in 1200, 1400, 1600, 1800 and 2000 kcal / day. All participants will be categorized according to one of the five levels of the diet's energy content. In addition, all patients will receive a leaflet with nutritional guidelines according to their diet.

During the study, participants will be required to maintain their medication consumption, if any, as prescribed by a physician. To assess adherence to the diet, participants will consult with a nutritionist on a weekly basis and complete the 24-hour food recall.

It will be measured the pulse wave velocity.This outcome will be evaluated before the beginning of the diets and 6 weeks after the beginning of the diets.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Quadruple (Participant, Care Provider, Investigator, Outcomes Assessor)

入排标准

年龄范围
20 Years 至 59 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • Between 20 and 59 years old
  • Body mass index ≥ 25.0 kg/m²
  • Physically inactive (physical activity <150 min/week)

排除标准

  • Pregnant women
  • Vegetarians
  • Users of dietary supplements
  • Alcohol abusers (men: more than 4 doses in a single day or more than 14 doses per week; women: more than 3 doses in a single day or more than 7 doses per week)
  • Individuals with a previous diagnosis of hypertension
  • Chronic kidney disease
  • Type 1 or 2 diabetes mellitus
  • Hypothyroidism
  • Hyperthyroidism
  • Events in the last 6 months (coronary artery disease, acute myocardial infarction, cerebral vascular disease, peripheral arterial disease, or heart failure)

研究组 & 干预措施

Low glycemic load diet

Experimental

Foods with low glycemic index or glycemic load (brown rice, brown bread, whole wheat pasta, oat bran, yogurt, milk, apple, pear, peach)

干预措施: Low glycemic load diet (Other)

High glycemic load diet

Active Comparator

Foods with high glycemic index or glycemic load (white rice, white bread, corn flakes, mashed potatoes, orange juice, banana, persimmon, grape, raisins, honey, sugar)

干预措施: Low glycemic load diet (Other)

结局指标

主要结局

Pulse wave velocity

时间窗: 6 weeks

The calibrated and validated Mobil-O-Graph® portable monitor (IEM GmbH, Stolberg, Germany) will be used. This module is connected to a computer to record the brachial pulse wave. It performs pulse wave analysis based on the oscillometric method. The arterial pulsation generates pressure oscillations, which are transmitted to the blood pressure cuff and measured by the transducer to be interpreted by a specific software, recording the pulse wave of the brachial artery and deriving a pulse wave from the aortic arch. All measurements will be performed by the same evaluator on the right side of the volunteer, at rest. Subjects will be instructed to be with empty bladder, not to drink coffee 60 minutes before gauging and alcoholic beverage in the last 24 hours. The pulse wave velocity will be evaluated before the beginning of the diets and 6 weeks after the beginning of the diets.