跳至主要内容
临床试验/NCT06438692
NCT06438692招募中不适用

Clinical Study on the 2C3L Strategy Based on Marshall Venous Chemoablation for the Treatment of Persistent Atrial Fibrillation Combined With Heart Failure

Qianfoshan Hospital1 个研究点 分布在 1 个国家目标入组 130 人开始时间: 2022年6月16日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
130
试验地点
1
主要终点
Postoperative recurrence rate

研究概览

简要总结

(1) To evaluate the efficacy and safety of "2C3L" strategy combined with VOM anhydrous ethanol chemical ablation for persistent atrial fibrillation complicated with heart failure; (2) To evaluate the effectiveness of high-efficiency ablation of atrial fibrillation complicated with heart failure.

详细描述

2C3L ablation strategy: The electroanatomical mapping system was the Carto 3 V6 system of Johnson & Johnson, and the high-density mapping electrode (Pentaray) and cold saline perfusion pressure catheter (ST-SF) were used for ablation. Ablation parameters were set as follows: ablation power of 45 to 50 Watts (reduced to 25 Watts in the coronary vein and 35 Watts in the endocardium of the mitral isthmus), upper temperature limit of 43 ° C, and saline infusion rate of 15 mL/ min (changed to 30 mL/min in coronary veins), the pressure was controlled at 5-15 g, and the target AI was set: 480-500 for the anterior wall of the pulmonary vein, 350-380 for the posterior wall, 450 for the top of the left atrium, 600 for the mitral valve isthmus, and 450 for the tricuspid valve isthmus. A single catheter procedure was performed in the left atrium, and the ablation endpoint was to achieve continuous bilateral circumferential pulmonary vein damage with loss of intrapulmonary vein potential, which was further confirmed after conversion to sinus rhythm. During left pulmonary vein ablation, the top and posterior wall of left pulmonary vein were ablated first. If pulmonary vein isolation was achieved, no further intervention was performed on the anterior edge of left pulmonary vein. The ablation of the mitral annulus started from about 1 cm away from the junction between the VOM and the coronary vein, and continued to the low-voltage area. Ablation was performed in the corresponding epicardium, namely the coronary vein. Finally, the isthmus of the tricuspid valve was ablated from 6:00 to the inferior vena cava. If the patient still had atrial fibrillation or atrial flutter after the above ablation, 200 J direct current was used to cardioversion the sinus rhythm, and the complete block of each ablation path was verified by pacing during sinus rhythm. In the ablation-only group, catheter ablation was used only to these end points. The operation time was from the start of venipuncture to the removal of sheath tube. The melting time was the cumulative ablation time.

VOM absolute ethanol chemical ablation: The SL1 long sheath was delivered to the opening of the coronary sinus through the right femoral vein, and the right coronary finger guide tube (JR4) was placed to the opening of the coronary sinus. The guide tube was rotated clockwise, and the tip of the guide catheter was pointed in the posterior-superior direction under the right anterior oblique 30 degree fluoroscopy. The BMW guide wire was sent to the proximal end of VOM, and the OTW balloon was sent to the middle and distal end of VOM. The balloon was expanded, and after the BMW guide wire was removed, the course of VOM and whether there was regurgitation were observed by angiography to ensure the complete occlusion of VOM. Anhydrous ethanol was injected in fractions via the OTW balloon.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Triple (Participant, Investigator, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • age:18y-80y
  • First ablation on non valvular atrial fibrillation
  • Persistent atrial fibrillation with LVEF≤40%
  • The patient has symptoms related to atrial fibrillation, including but not limited to palpitations, premonitory syncope, syncope, fatigue, and shortness of breath, and is evaluated for clinical cardiac function between NYHA II-IV levels
  • No response to antiarrhythmic drugs, unacceptable side effects, or unwillingness to take antiarrhythmic drugs.

排除标准

  • Paroxysmal atrial fibrillation
  • Atrial fibrillation secondary to obvious reversible causes
  • Echocardiography: Parasternal long axis section, left atrial diameter ≥ 60mm
  • Receiving dual antithrombotic therapy
  • Contraindications to the use of oral anticoagulants
  • Contraindications to right or left cardiac catheterization
  • Life expectancy<1 year (such as advanced malignant tumors, advanced kidney disease, etc.)
  • Unable to discontinue antiarrhythmic drugs due to reasons other than atrial fibrillation

结局指标

主要结局

Postoperative recurrence rate

时间窗: 12 months after operation

Postoperative recurrence rate was evaluated by holter monitoring.

次要结局

未报告次要终点

研究者

发起方
Qianfoshan Hospital
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验