跳至主要内容
临床试验/NCT03344978
NCT03344978撤回不适用

Cardboard Cot in Neonatal Thermoregulation: A Randomized Cross Over Trial in Prevention of Moderate or Severe Hypothermia in Preterm Infants Requiring at Least 1 Week of Incubator

University of Alabama at Birmingham0 个研究点开始时间: 2019年6月11日最近更新:
适应症

试验速览

阶段
不适用
状态
撤回
主要终点
Moderate (32.-35.9° C) or Severe (<32.0° C) hypothermia per Axillary Temperature

研究概览

简要总结

This study will determine whether the efficacy of Mylar-lined cardboard cots is equivalent to traditional incubators in their ability to prevent hypothermia (axillary temperature < 36° C) in preterm neonates <36 6/7 weeks gestational age in a randomized cross-over designed trial. Infants will be randomized to receive care in the cardboard cot or incubator and then cross over to the other device for 24 hour periods, rotating for a total of 96 hours total trial time.

详细描述

The aim of the trial is to determine whether a corrugated cardboard cot will assist in maintaining infant axillary temperatures comparing it to the temperatures of the same infant being nursed in low heat incubators. The study will be done in the context of standard medical care, including the WHO thermoregulation protocol (warm delivery rooms, immediate drying after birth, early and exclusive breastfeeding, postponement of bathing and weighing, and appropriate bundling).

The cardboard cot is approximately 24 inches long to accommodate the length of the infant and about 12 inches wide to accommodate term infants, even beyond the first months after birth. The cots are fully lined with a reflective metallized film sheet of Mylar. The cot will be covered with a cardboard piece also lined in reflective film up to about the infant's shoulders so that the infant's face is visible. Attached to the lid is a 5 inch cardboard flap lined with reflective film which folds down into the body of the cot to reduce heat loss.

Infants ≤ 36 6/7 weeks gestation will be randomized to receive care in a cardboard cot or an incubator. Infants will begin care in one device and after 24 hours will cross over to the other device for another 24 hours. The process will be repeated once more for a total of 96 hours of study duration. The infants will be normothermic and stable when they are enrolled in the trial. Axillary temperatures will be measured at 1 hr, 6 hours and 24 hours after being placed in the cost or incubator. Infants with observed hypothermia (<36° C) will have measures taken to increase temperature (i.e. adding blankets, hat).

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Prevention
盲法
None

入排标准

年龄范围
1 Minute 至 5 Days(Child)
性别
All
接受健康志愿者

入选标准

  • Estimated gestational age < 36 6/7 weeks
  • Hospitalized in the NICU at University Teaching Hospital in Zambia
  • Requiring incubator/radiant warmer for at least 1 week

排除标准

  • Abdominal wall defect or myelomeningocele
  • Major congenital anomalies
  • Blistering skin disorder
  • Suspected Sepsis
  • Requiring ongoing respiratory support

结局指标

主要结局

Moderate (32.-35.9° C) or Severe (<32.0° C) hypothermia per Axillary Temperature

时间窗: 1 hour after placement in warming device

Temperature taken via axilla for 1 minute duration

Moderate (32.0-35.9° C) or Severe (<32.0° C) hypothermia per Axillary Temperature

时间窗: 6 hours after placement in warming device

Temperature taken via axilla for 1 minute duration

Moderate (32.-35.9° C) or Severe (<32.0°C) hypothermia per Axillary Temperature

时间窗: 24 hours after placement in warming device

Temperature taken via axilla for 1 minute duration

次要结局

  • Normothermia (Axillary temperature 36.0 - 38.0° C)(1-96 hours after beginning of study)
  • Rate of Severe hypothermia (<32.0° C) after placement in warming device(24 hours after placement in warming device)
  • Rate of Moderate hypothermia (32.0-35.9° C) after placement in warming device(24 hours after placement in warming device)
  • Rate of Hyperthermia (>38.0°C) after placement in warming device(4 months)
  • Hypothermia (Axillary temperature < 36.0° C)(1-96 hours after beginning of study)
  • Mean Axillary Temperature in each device(4 months)
  • Rate of Moderate hypothermia (32.0-35.9°C) after placement in warming device(6 hours after placement in warming device)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Colm Travers

Principal Investigator

University of Alabama at Birmingham

相似试验