NCT06406101已完成不适用
Influence of CPR Surface Choice on Chest Compression Quality: A Randomized Manikin Study Comparing Bed and Floor Settings
适应症
干预措施
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 147
- 试验地点
- 1
- 主要终点
- Compressions Mean Depth
研究概览
简要总结
The objective of our randomized simulation study on mannequins with a population of Basic Life Support students is to compare the quality of chest compressions, taking depth as the main variable, in two simulated scenarios of out-of-hospital cardiac arrest on a bed: one where Cardiopulmonary Resuscitation is performed on the bed and another where the patient is transferred to the ground for Cardiopulmonary Resuscitation.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Those individuals who sign the informed consent and do not meet
排除标准
- •Exclusion Criteria: Individuals with any limitation or contraindication for physical exercise:
- •Arthritis
- •Heart disease
- •Advanced lung disease
- •Severe physical disability
- •Morbid obesity
- •Chronic fatigue
- •Pregnancy
- •Withdrawal Criteria:
- •Those individuals who, due to limitations in physical exercise, do not reach 2 minutes of compressions
- •Students who have not obtained the certificate of successfully completing the course.
研究组 & 干预措施
Bed
Active Comparator
干预措施: Bed (Other)
Floor
Experimental
干预措施: Floor (Other)
结局指标
主要结局
Compressions Mean Depth
时间窗: On the day of the simulation
Chest Compressions Mean Depth
次要结局
- Time to first chest compression(On the day of the simulation)
- Total number of chest compressions(On the day of the simulation)
- Percentage of chest compressions with correct position of hands(On the day of the simulation)
- Percentage of chest compressions with correct frequency(On the day of the simulation)
- Borg Scale for Fatigability(On the day of the simulation)
- Mean frequency of chest compressions(On the day of the simulation)
- Effectiveness of Chest Compressions(On the day of the simulation)
- Percentage of chest compressions whit correct depth (5-6cm)(On the day of the simulation)
- Percentage of chest compressions with correct release(On the day of the simulation)
研究者
Enrique Carrero
Director
Hospital Clinic of Barcelona
研究点 (1)
Loading locations...
相似试验
已完成
3 期
Dispatcher-Assisted Resuscitation Trial (DART)Heart ArrestNCT00219687Public Health - Seattle and King County5,494
已完成
不适用
Evaluation of Efficacy of the Prototype RPC (Rapid Pulse Confirmation) Device in Detecting Return of Pulsatile Flow in Patients Preparing to Separate From CPB (Cardiopulmonary Bypass)Cardiac ArrestCirculatory FailureNCT04526249Michael Kyle Ritchie10
已完成
不适用
A Mannequin Study to Assess Various CPR Training Methods Using a Student PopulationHeart DiseaseCardiac ArrestNCT01833910University of Pennsylvania25
已完成
不适用
CPR Rescuer Fatigue on Chest Compression EffectivenessRescuer Fatigue During CPRNCT01117896Children's Hospital of Philadelphia106
Unknown
不适用
The Effect of Chest Compression and Ventilation Coordination During Cardiopulmonary Resuscitation.Out-of-Hospital Cardiac ArrestSudden Cardiac DeathNCT02056509National Taiwan University Hospital50