Accuracy of Advanced Treatment Planning Software for Static Computer Guided Surgery ( Blue Sky Plan Bio, Exoplan, Real Guide Computer Software)
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 入组人数
- 60
- 主要终点
- deviation between planned and actual implant position when using different planning software
研究概览
简要总结
This study will be conducted to investigate the accuracy of Blue sky plan bio , exoplan ,and real guide advanced treatment planning software required for static computer guided surgery designing and manufacturing.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Treatment
- 盲法
- Single (Participant)
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •partially edentulous adults with at least three teeth remaining.
- •an expected sufficient bone volume to perform implant insertion with at least a 3.5mm Cybermed dental implant without simultaneous bone augmentation.
- •extractions performed at least 3 months earlier.
- •potential earlier sinus grafting was performed at least 6 months prior to implant placement.
- •Patients with absence of any periodontal problems in the adjacent teeth.
- •7- stable medical condition to undergo implant surgery (ASA 1 or 2).
排除标准
- •Physical or psychological disorders generally prohibiting implant therapy. After initial screening.
- •Patients with a history of bruxism
- •Patients with over eruption of the opposing tooth.
研究组 & 干预措施
blue sky plan group
surgical guide will be fabricated using Blue sky plan computer software
干预措施: dental implant will be inserted using surgical guide (Procedure)
blue sky plan group
surgical guide will be fabricated using Blue sky plan computer software
干预措施: dental implant (Procedure)
exoplan group
surgical guide will be fabricated using Exoplan computer software
干预措施: dental implant will be inserted using surgical guide (Procedure)
exoplan group
surgical guide will be fabricated using Exoplan computer software
干预措施: dental implant (Procedure)
Real guide group
surgical guide will be fabricated using Real guide computer software
干预措施: dental implant will be inserted using surgical guide (Procedure)
Real guide group
surgical guide will be fabricated using Real guide computer software
干预措施: dental implant (Procedure)
结局指标
主要结局
deviation between planned and actual implant position when using different planning software
时间窗: 14 days
measurement will be done by superimposition two CBCTs showing the pre-operation ( planned) and post operation implant position which will reveal the deviation in millimeter in regards to entry point ,apical ,and angular deviation of dental implant using specified tool within the planning software
次要结局
未报告次要终点
研究者
Hussein Anssari
PhD student in oral and maxillofacial surgery
University of Baghdad