Assessing Repeatability and Intra-individual Variability in [O15]H2O-PET Myocardial Perfusion Imaging
试验速览
- 阶段
- 不适用
- 状态
- 进行中(未招募)
- 发起方
- 入组人数
- 20
- 试验地点
- 1
- 主要终点
- [O15]H2O-PET-MPI variability and repeatability coefficient estimated from 20 patients having [O15]H2O-PET-MPI done twice
研究概览
简要总结
This study wish to assess the reproducibility of baseline and hyperemic myocardial blood flow as well as myocardial blood flow reserve measurements with [O15]H2O-PET-MPI.
详细描述
Myocardial perfusion imaging (MPI) using [O15]H2O-PET-CT represents a validated technique for quantitatively assessing myocardial blood flow (MBF) and myocardial flow reserve (MFR).
With advancements in scanner and software technology, it is now possible to accurately quantify both global and regional MBF in clinical PET-MPI studies. Reduced stress MBF or MFR, as determined by [O15]H2O-PET-MPI, is a reliable indicator for detecting hemodynamically significant coronary artery stenosis. Additionally, MBF and MFR offer valuable prognostic insights into mortality and the risk of myocardial infarction. Clinical experience suggests that implementing [O15]H2O-PET-MPI for coronary artery disease evaluation is not only feasible but also aids in making informed decisions regarding revascularization.
This study wish to assess the reproducibility of baseline and hyperemic myocardial blood flow as well as myocardial blood flow reserve measurements with [O15]H2O-PET-MPI.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Prospective
入排标准
- 年龄范围
- 50 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients > 50 years of age referred for [O15]H2O-PET-MPI by the dept. of cardiology on clinical indication with symptoms suggestive of myocardial ischemia, primarily angina.
- •Willing to repeat the [O15]H2O-PET-MPI
- •Normal left ventricular ejection fraction (EF > 45), as assessed from recent (max 1 year old) echocardiography description in medical journal.
排除标准
- •Cardiovascular event in between scans (defined as hospitalization for cardiovascular event).
- •History of myocardial infarction
- •Regional perfusion deficits on the primary [O15]H2O-PET-MPI clinically suspected as a sign of significant coronary stenosis.
- •Unstable angina
- •Severe Chronic Obstructive Pulmonary Disease (COPD)
- •Severe asthma
- •Claustrophobia
- •Acute illness
- •Significant language barrier, estimated by the investigator not being able to understand the study information sufficiently.
结局指标
主要结局
[O15]H2O-PET-MPI variability and repeatability coefficient estimated from 20 patients having [O15]H2O-PET-MPI done twice
时间窗: 8 months
In this study two \[O15\]H2O-PET-CT scans in the same induvidual at two different timepoints will be conducted. This will allow a variability estimation (for each meassurement eg rest MBF (ml/g/min), stress MBF (ml/g/min)) and thereby a calculated repeatability coefficient.
次要结局
未报告次要终点
研究者
Peter Hovind
Head of department, Department of Clinical Physiology and Nuclear Medicine and PET
Bispebjerg Hospital
