跳至主要内容
临床试验/NCT05800171
NCT05800171招募中不适用

A Prospective Cohort Study on the Efficacy of Single Use Disposable Elevator Cap (DEC) Duodenoscopy

Seoul National University Hospital1 个研究点 分布在 1 个国家目标入组 5,000 人开始时间: 2023年4月24日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
5,000
试验地点
1
主要终点
Incidence of cholangitis cuased by MDR pathogens

研究概览

简要总结

The goal of this prospective cohort observational study is to compare incidence of cholangitis cause by multi-drug resistant pathogens in patient who underwent ERCP.

The main question it aims to answer are:

  • Is the single use disposable elevator cap duodenoscope more effective in preventing cholangitis caused by MDR than fixed cap duodeoscope?
  • Is the single use disposable elevator cap duodenoscope more effective in preventing severe cholangitis than fixed cap duodenoscope?

Participants will undergo and ERCP procedure. Among the patients who received the procedure, those who developed cholangitis after procedure will treated with antibiotics after blood culture test. The result of the post procedure cholangitis group's blood culture test and lab data including LFT will be collected. Researches will compare single use disposable elevator cap duodenoscope group and fixed distal cap duodenoscope group to see if there is difference in the incidence of cholangitis caused by MDR pathogens.

详细描述

Insufficient disinfection of duodenoscopes, particularly the elevator site, can cause ERCP-related infections and serve as a significant source of multidrug-resistant (MDR) infection. To address this issue, a disposable elevator cap (DEC) was developed, and a recent randomized clinical trial demonstrated its effectiveness in reducing contamination following high-level disinfection. However, there is limited evidence in actual clinical practice to reduce cholangitis caused by MDR pathogens. This study aimed to compare the efficacy of the novel DEC duodenoscope with the standard duodenoscope in preventing infection transmission.

We conducted a prospective non-randomized cohort study in a single institution comparing baseline characteristics, technical performance, and incidence of acute cholangitis, including MDR pathogen, in 95 patients using a standard duodenoscope and 101 patients using a DEC duodenoscope.

Age, sex, comorbidities, and indication for ERCP were similar between the two groups. However, the standard duodenoscope group had a higher proportion of naïve papilla (51% vs. 34%, p = 0.04), while the technical success rate was slightly higher in the DEC duodenoscope group (95% vs. 85%, p = 0.15). The rates of procedure-related adverse events were similar between the two groups (16% for DEC vs. 15% for standard). The incidence of post-ERCP cholangitis was also similar (10% for DEC vs. 11% for standard, p = 0.90). The proportion of post-ERCP cholangitis caused by MDR pathogens was similar in the two groups (1% for DEC vs. 2% for standard, p = 0.39).

This study suggests that the technical performance of the DEC duodenoscope is similar to that of the standard duodenoscope. However, more clinical data are needed to confirm the efficacy of the DEC duodenoscope in preventing ERCP-related infection transmission.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
19 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient who undergone ERCP
  • 19 years age or older

排除标准

  • Patients who already undergone biliary drainage
  • Patient who already confirmed of multidrug resistant bacterial infection
  • Pregnant women

结局指标

主要结局

Incidence of cholangitis cuased by MDR pathogens

时间窗: complication with in 2weeks after ERCP

percentage

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验