to Explore the Characteristics of Mean Airway Pressure, Oscillatory Amplitude and Power Spectral Density (PSD) of Oscillatory Airway Pressure That Generate by Various Loaded and Flow Rate During Expiration and Inspiration in Healthy Subjects
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 10
- 试验地点
- 2
- 主要终点
- PSD of oscillatory airway pressure
研究概览
简要总结
the aim of this study are to explore the characteristics of mean airway pressure, oscillatory amplitude and power spectral density (PSD) of oscillatory airway pressure that generate by various loaded and flow rate during expiration and inspiration in healthy subjects and to explore the best loaded and flow rate for airway secretion clearance using the BreatheMAX® device
详细描述
For inspiratory group, the resistive load 3, 4, 5, 6 and 7 cm H2O were test with three flow rate: 0.2, 0.4, and 0.6 L/sec in each load. In each flow rate, the subjects were instructed to inspire as deeply as possible with steady flow rate for 3 seconds with end-inspiratory pause for 2-3 seconds through the inspiratory circuit and follow by passive exhalation. For expiratory group, the resistive load and flow rate were test similar inspiratory group. In each flow rate, the subjects were instructed to inspire as deeply as possible through the nose with end-inspiratory pause for 2-3 seconds and partially forced exhalation with reach to 1/3 of expiratory reserve volume (ERV) for at least 3 seconds through expiratory circuit
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Other
- 盲法
- Single (Investigator)
入排标准
- 年龄范围
- 18 Years 至 35 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •the healthy subjects
- •able to breathe against resistive load with the BreatheMAX device
- •good conscious and cooperation
排除标准
- 未提供
研究组 & 干预措施
Inspiratory group
the subjects will be instructed to inspire as deeply as possible with steady flow rate for 3 seconds with end-inspiratory pause for 2-3 seconds through the inspiratory circuit and follow by passive exhalation
干预措施: BreatheMAX breathing device (Device)
expiratory group
the subjects will be instructed to inspire as deeply as possible through the nose with end-inspiratory pause for 2-3 seconds and partially forced exhalation with reach to 1/3 of expiratory reserve volume (ERV) for at least 3 seconds through expiratory circuit
干预措施: BreatheMAX breathing device (Device)
结局指标
主要结局
PSD of oscillatory airway pressure
时间窗: 5 seconds during inspiration and expiration testing period
次要结局
- oscillatory amplitude(5 seconds during inspiration and expiration testing period)
- mean airway pressure(5 seconds during inspiration and expiration testing period)
研究者
Sujittra Kluayhomthong
Principle Inveatigator
Khon Kaen University