跳至主要内容
临床试验/NCT04796597
NCT04796597已完成不适用

Early Feasibility Study on Epios Leads

Wyss Center for Bio and Neuroengineering2 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2021年3月23日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
10
试验地点
2
主要终点
Feasibility of inserting Epios Leads in step 1

研究概览

简要总结

The Epios early feasibility study aims to explore the uses of novel sub-scalp lead devices in the detection of epileptic seizures. Epios leads are inserted subcutaneously through dedicated tunneling toolkits and have been designed for continuous EEG recording in inpatients.

This clinical investigation is part of a stepwise program to validate the entire Epios system and it starts with the validation of the Epios leads alone in this two steps study.

详细描述

According to the state of the art, epilepsy is defined as the spontaneous recurrence of seizures at random intervals. When epilepsy is drug refractory, management plans rely entirely on seizure self-reporting. However, it is now established that self-reports of seizure burdens are inaccurate. The reasons for this are multiple, but important ones include the fact that seizures can affect brain regions involved in awareness and memory, and that epilepsy patient can also have persistent cognitive deficits, so they do not recall having a seizure. EEG caps are the standard tool for monitoring brain waves, but this technology is typically used for less than an hour and rarely can be managed for a period of a week or so because of the need for continual technical interventions, like reapplying electrodes to the skin. Thus, there is no way to fill the gap in the ability to obtain monitoring of EEG for weeks, months or longer.

Given the unmet need for the objective monitoring of epileptic seizures in ambulatory patients, innovative solutions are under development.

The Epios device under investigation in this study consists in novel sub-scalp leads implanted between the scalp and the skull through an insertion tunneling toolkit for EEG monitoring in short-term conditions.

This clinical investigation is part of a stepwise program to validate the entire Epios system and it starts with the validation of the Epios leads alone in step 1 and step 2.

Step 1 is an intra-operative step only, where a 10-minute long EEG recording is performed using the Epios leads, after the patient has undergone general anesthesia for his/her clinically-indicated brain surgery. The study material is removed before skin closure and end of anesthesia.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Sequential
主要目的
Device Feasibility
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age ≥ 18 years
  • Informed Consent as documented by signature
  • Neurosurgical patient, i.e. patient under surgical care who will undergo one of the following specific procedures:
  • Step 1: Patient in the operating room undergoing clinically indicated brain surgery either for resection (e.g. tumor), cortical mapping (including awake) or intracranial electrode implantation
  • Step 2: patients with pharmaco-resistant epilepsy hospitalized in the epilepsy monitoring unit (EMU) for the purpose of intracranial EEG monitoring

排除标准

  • Patients with increased risk of infection
  • Pregnant or breast-feeding women
  • Severe neuropsychiatric disorders
  • Severe cognitive problems: the patients need to be able to understand instructions and provide consent
  • Chronic headache disorders, such as migraine and related disorders, as well as trigeminal neuralgia
  • Medical conditions contraindicating cranial surgery (e.g. skin disorders causing poor wound healing, blood or cardiac disorder requiring chronic anti-coagulation, osteomyelitis, active systemic infection, haemorrhagic disease, diabetes, hepatitis, any documented allergy to implantation material)
  • Other chronic, unstable medical conditions that could interfere with subject participation
  • Existing scalp lesions or skin breakdown
  • Scalp infections
  • Implanted neurosurgical devices that are incompatible with Epios leads, which may include DBS leads
  • Subjects who are allergic to the anaesthetics used in the implantation

结局指标

主要结局

Feasibility of inserting Epios Leads in step 1

时间窗: Through the length of Step 1, up to 24 weeks

The primary outcome of step 1 is to assess the feasibility of inserting two different EEG electrode leads (tubular and flat) under the human scalp via the tunneling tools. Measurement parameter: Length of each incision measured in centimeters.

Safety assessed as number of adverse events related to study device compared to the total number of adverse events for Step 1

时间窗: Through the length of Step 1, up to 24 weeks

Patients' safety monitoring is ensured along the clinical study in a descriptive manner. Safety criteria resulting or not in early device explantation have been established to monitor patients' safety.

Feasibility of inserting Epios Leads in step 2

时间窗: Through the length of Step 2 , up to 1 year

The primary outcome of step 2 is to assess the feasibility of inserting Leads tridents (either tubular or flat depending on the outcome from step 1) under the human scalp via the tunneling tools. Measurement parameter: Length of each incision measured in millimeters.

Safety assessed as number of adverse events related to study device compared to the total number of adverse events for Step 2

时间窗: Through the length of Step 2 , up to 1 year

Patients' safety monitoring is ensured along the clinical study in a descriptive manner. Safety criteria resulting or not in early device explantation have been established to monitor patients' safety.

次要结局

  • Capability of tubular leads to record subscalp EEG signals in Step 1(Through the length of Step 1, up to 24 weeks)
  • Capability of Epios leads to record epileptiform EEG signals from the sub-scalp space in Step 2(Through the length of Step 2 , up to 1 year)
  • Capability of flat leads to record subscalp EEG signals in Step 1(Through the length of Step 1, up to 24 weeks)

研究者

发起方
Wyss Center for Bio and Neuroengineering
申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验