A New Cochlear Implant Electrode With A "Cork" Type Stopper For Inner Ear Malformations

Hacettepe University0 个研究点目标入组 50 人开始时间: 2013年5月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
50
主要终点
CSF leak

研究概览

简要总结

The custom made device was produced by Med-El Company. It has a "cork" like stopper instead of the usual silicon ring to prevent gusher. There are two types of electrodes consisting of different length. Standard one is 25 mm (contact space 1.7 mm) and the short one is 20 mm (contact space 1.3 mm). It was used in 50 patients with different inner ear malformations. Thirteen patients had gusher, and 11 patients oozing during cochleostomy. One patient with initial prototype of the cork electrode had to be revised because of persistent oozing around the electrode. Another patient had slow extrusion of the electrode most probably due to CSF (cerebrospinal fluid) pulsation and had to be revised. Both patients had no more CSF fistula.

CSF fistula in inner ear malformations is a serious situation which may lead to recurrent meningitis. The new cochlear implant electrode with "cork" stopper looks promising in preventing the postoperative CSF leak around the electrode.

详细描述

Gusher in inner ear malformations is common in patients with incomplete partition type-I, and III. It is also common in less severe form as oozing in incomplete partition type II and large vestibular aqueduct. It is important to prevent CSF escape around the cochlear implant electrode to prevent meningitis.

The custom made device was produced by Med-El Company. It has a "cork" like stopper instead of the usual silicon ring to prevent gusher. There are two types of electrodes consisting of different length. Standard one is 25 mm (contact space 1.7 mm) and the short one is 20 mm (contact space 1.3 mm). It was used in 50 patients with different inner ear malformations.

Thirteen patients had gusher, and 11 patients oozing during cochleostomy. One patient with initial prototype of the cork electrode had to be revised because of persistent oozing around the electrode. Another patient had slow extrusion of the electrode most probably due to CSF pulsation and had to be revised. Both patients had no more CSF fistula.

CSF fistula in inner ear malformations is a serious situation which may lead to recurrent meningitis. The new cochlear implant electrode with "cork" stopper looks promising in preventing the postoperative CSF leak around the electrode.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

性别
All
接受健康志愿者

入选标准

  • Must have an inner ear malformation
  • Must meet the criteria for cochlear implantation

排除标准

  • Prior cochlear implantation surgery

结局指标

主要结局

CSF leak

时间窗: Up to 1 year

Occurrence of CSF leak after the surgery.

次要结局

  • Meningitis(Up to 1 year)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Münir Demir Bajin

MD

Hacettepe University