SpO2 Accuracy Validation of Pulse Oximetry Systems During Motion and Non-Motion Conditions of Induced Hypoxia as Compared to Arterial Blood CO-Oximetry
适应症
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 13
- 试验地点
- 1
- 主要终点
- accuracy value (Arms) for %SpO2 over the range of 70-100% in motion and non-motion
研究概览
简要总结
Study to evaluate the %SpO2 accuracy performance of the Nonin Medical pulse oximetry systems.
详细描述
Study to evaluate the %SpO2 accuracy performance of the Nonin Medical pulse oximetry systems during motion and non-motion.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 45 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •The subject is male or female
- •The subject is of any racial or ethnic group
- •The subject is > 30 kg (>66 pounds) in weight (self-reported)
- •The subject has at least one finger height of 0.2 - 1.0 inch (based on measurement)
- •The subject is between 18 years and 45 years of age (self=reported)
- •The subject shows no evidence of medical problems as indicated by satisfactory completion of the health assessment form
- •The subject has given written informed consent to participate in the study
- •The subject is both willing and able to comply with study procedures.
排除标准
- •The subject has a BMI greater than 31 (based on weight and height)
- •The subject has had any relevant injury at the sensor location site (self-reported)
- •The subject has deformities or abnormalities that may prevent proper application of the device under test (based on examination)
- •The subject is current smoker (self-reported)
- •The subject has a known respiratory condition (self-reported)
- •The subject has a known heart or cardiovascular condition (self-reported)
- •The subject is currently pregnant (self-reported)
- •The subject is actively trying to get pregnant (self-reported)
- •The subject has a clotting disorder (self-reported)
- •The subject has Raynaud's Disease (self-reported)
- •The subject is known to have a hemoglobinopathy (self-reported)
- •The subject is on blood thinners or medication with aspirin (self-reported)
- •The subject has unacceptable collateral circulation from the ulnar artery (based on examination)
- •The subject is unwilling or unable to provide written informed consent to participate in the study
- •The subject is unwilling or unable to comply with the study procedures
- •The subject has another health condition which in the opinion of the principal investigator makes him/her unsuitable for testing.
结局指标
主要结局
accuracy value (Arms) for %SpO2 over the range of 70-100% in motion and non-motion
时间窗: 3 days
次要结局
未报告次要终点
研究者
研究点 (1)
Loading locations...
相似试验
撤回
不适用
Accuracy Validation of a Pulse Oximetry MonitorHealthyNCT02506010Medtronic - MITG
已完成
不适用
SpO2 System Accuracy Testing With Different SensorsPulse OximetryNCT01613222GE Healthcare63
已完成
不适用
Polso SpO2 Accuracy Validation StudyHypoxiaNCT03735329ChroniSense Medical Ltd.10
Unknown
不适用
Hypoxia Blood Validation in Multiple Pulse OximetersHypoxiaNCT00881829Clinimark, LLC500
已完成
不适用
Fingertip Pulse Oximeter Clinical TestSPO2NCT01605955Andon Health Co., Ltd10