跳至主要内容
临床试验/NCT04828590
NCT04828590已完成不适用

Assessment of the DiAgnostic Performance of DeepVessel FFR in SuspecTed Coronary Artery Disease

Keya Medical10 个研究点 分布在 5 个国家目标入组 302 人开始时间: 2020年8月10日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
302
试验地点
10
主要终点
Sensitivity of DVFFR at the vessel level in identifying ischemic lesions, i.e. DVFFR value≤0.80, from coronary CTA images, using ICA-FFR measurement as a reference standard.

研究概览

简要总结

DEEPVESSEL FFR is a medical device that is designed to extract three- dimensional coronary tree structures and generate computed tomography-derived fraction flow reserve (FFR) values from coronary CT angiogram images. The primary objective of this multi-center clinical validation study is to validate the clinical performance of DEEPVESSEL FFR in identifying patients with myocardial ischemia due to significant obstructive coronary artery diseases.

详细描述

Coronary artery disease (CAD) is the most common type of heart disease, and it is the leading cause of death worldwide in both men and women. CAD happens when the coronary arteries become hardened and narrowed, which is due to the buildup of cholesterol-containing deposits-plaque on the inner vessel wall. As the plaque grows, less blood can flow through the arteries due to the vessel narrowing. Decreased blood flow can then lead to chest pain (angina), shortness of breath, or even a heart attack.

Fractional flow reserve (FFR), a measure of blood flow reduction caused by vessel narrowing, is accepted as gold standard for assessing the functional significance of stenotic lesions. Multiple randomized trials have demonstrated that FFR has excellent diagnostic value in identifying functionally significant lesions and guiding coronary revascularization procedures. However, FFR is measured invasively through a pressure wire-based cardiac catheter procedure in the catheterization lab. Current guidelines recommend assessing myocardial ischemia of stable patients with CAD through non-invasive functional testing before considering invasive coronary angiography (ICA) or conducting myocardial revascularization.

DEEPVESSEL FFR (DVFFR) is a software medical device that is designed to extract three- dimensional coronary tree structures and generate computed tomography -derived FFR values from coronary CT angiogram (CTA) images. It uses deep learning neural networks that encode imaging, structural, and functional characteristics of coronary arteries and learn complex mapping between FFR values and the encoded information. The quantitative FFR analysis based on the coronary CTA images can help clinicians assess the physiological function in patients with CAD non-invasively.

The primary objective of this study is to evaluate the diagnostic performance of DVFFR software in identifying patients with significant obstructive CAD causing myocardial ischemia, using invasively measured ICA FFR as the reference standard.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Retrospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Patients' age ≥18 years;
  • •Has coronary CTA images acquired by ≥64 multidetector row CT scanner, no earlier than 2016 and within 60 days of the ICA-FFR procedure;
  • •Coronary CTA image shows at least one vessel segment (≥2mm diameter) with a diameter stenosis of 30%-90%;

排除标准

  • •Patients with any of the following conditions at the time of CTA imaging:
  • •Acute myocardial infarction;
  • •Unstable angina;
  • •Pulmonary edema;
  • •Heart function classification level III and IV (NYHA heart function classification);
  • •Implantable cardioverter defibrillator (ICD);
  • •Prior percutaneous coronary intervention (PCI) or pacemaker surgery;
  • •Prior coronary artery bypass grafting (CABG) surgery;
  • •Prior heart valve replacement;
  • •Prior history of complex congenital heart disease;
  • •Prior history of cardiomyopathy;
  • •Coronary total occlusion.

结局指标

主要结局

Sensitivity of DVFFR at the vessel level in identifying ischemic lesions, i.e. DVFFR value≤0.80, from coronary CTA images, using ICA-FFR measurement as a reference standard.

时间窗: through study completion, an average of 1 year

On the vessel level, if a vessel with at least one stenosis lesion with a FFR measurement less or equal to 0.80, this vessel is considered to be ischemic. A true positive on the vessel level is defined as a vessel containing at least one stenosis with DVFFR value ≤0.80 and its corresponding reference ICA-FFR value is also ≤0.80.

Specificity of DVFFR at the vessel level in identifying ischemic lesions, i.e. DVFFR value≤0.80, from coronary CTA images, using ICA-FFR measurement as a reference standard.

时间窗: through study completion, an average of 1 year

On the vessel level, if a vessel with at least one stenosis lesion with a FFR measurement less or equal to 0.80, this vessel is considered to be ischemic. A true positive on the vessel level is defined as a vessel containing at least one stenosis with DVFFR value ≤0.80 and its corresponding reference ICA-FFR value is also ≤0.80.

次要结局

  • Diagnostic performance including sensitivity, specificity, accuracy, PPV and NPV of DVFFR at the patient level(through study completion, an average of 1 year)
  • Per-vessel Pearson correlation coefficient between DVFFR and ICA-FFR values(through study completion, an average of 1 year)
  • Diagnostic performance (including sensitivity, specificity, accuracy, PPV and NPV) in detecting hemodynamically significant coronary obstruction using DVFFR and coronary CTA alone, on both vessel level and patient level.(through study completion, an average of 1 year)
  • Stratified analyses on different subgroups of subjects' data(through study completion, an average of 1 year)
  • Diagnostic accuracy, positive predictive value (PPV) and negative predictive value (NPV) of DVFFR at the vessel level(through study completion, an average of 1 year)

研究者

发起方
Keya Medical
申办方类型
Industry
责任方
Sponsor

研究点 (10)

Loading locations...