Safety and Efficacy of Endovascular Treatment of Intracranial Aneurysms With Surpass Elite With GUARDian Flow Diverter

Stryker Neurovascular12 个研究点 分布在 1 个国家目标入组 183 人开始时间: 2025年6月20日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
183
试验地点
12
主要终点
The primary efficacy endpoint: Number of subjects with 100% occlusion of the target aneurysm without significant parent artery stenosis, and with no target aneurysm retreatment through the 12-month follow-up visit timepoint.

研究概览

简要总结

The objective of the Safety and Efficacy of Endovascular Treatment of Intracranial Aneurysms with Surpass Elite with GUARDian Flow Diverter (GUARD) trial is to evaluate the safety and efficacy of the Surpass Elite with Guardian Flow Diverter System (FDS) in the treatment of unruptured, wide-neck saccular or fusiform, intracranial aneurysms (IAs) located on the internal carotid artery (ICA) or its branches.

详细描述

The Surpass Elite with Guardian Flow Diverter System is indicated for use in the endovascular treatment of adults (age 18 or above) with unruptured wide-neck saccular or fusiform intracranial aneurysms arising from a parent vessel with a diameter ≥ 3.0 millimeters (mm) and ≤ 6.0 mm and located on the ICA or its branches.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Age is ≥18 and ≤80 years at the time of consent
  • •Has a single unruptured target intracranial aneurysm (IA) of any size with the following characteristics:
  • •Is located on the internal carotid artery or its branches
  • •Has a wide neck (wide neck typically defined as neck width ≥ 4 millimeter (mm), or dome to neck ratio ≤ 2.0) or no discernible neck
  • •Aneurysm is either saccular or fusiform in nature
  • •Has a parent vessel diameter ≥ 3.0 mm to ≤ 6.0 mm at the largest diameter
  • •There is documented risk-benefit of endovascular treatment that outweighs the risks of intracranial aneurysm rupture during the subject's expected lifetime if left untreated.

排除标准

  • •Has an extradural target aneurysm
  • •Has a target aneurysm in the posterior circulation
  • •Perforator or branch vessel, inclusive of the posterior communicating artery, arises from the target aneurysm body or neck (branches or arteries must arise or connect from the parent vessel separate from the aneurysm or neck to not be excluded from trial)
  • •Has a true bifurcation aneurysm, defined as an aneurysm (saccular or non-saccular) located at a point of vessel bifurcation
  • •Has vessel characteristics, such as severe tortuosity (cavernous Internal Carotid Artery (cICA) Type IV1), stenosis (>70%), or morphology that would preclude safe endovascular access or proper deployment of the trial device to the target aneurysm
  • •Received previous treatment for the target aneurysm or parent artery where it would interfere with the placement or proper apposition of the device
  • •Has a medical contraindication to trial or procedure related antiplatelet medications (aspirin, clopidogrel/Plavix, ticagrelor, and heparin), local or general anesthesia, or life-threatening allergy to contrast dye
  • •Has a known severe allergy to nickel, chromium cobalt, tungsten, or platinum
  • •Patients with heparin hypersensitivity, including patients with a previous incident of Heparin-Induced Thrombocytopenia (HIT).
  • •Modified Rankin Score (mRS) assessment is ≥ 3 at pre-procedure exam
  • •Presence of unstable neurological deficit (i.e., worsening of clinical condition in the last 30 days prior to the index procedure)
  • •Subarachnoid hemorrhage occurred within 30 days prior to the index procedure
  • •Major surgery (including previous intracranial implant) either occurred within 30 days prior to the index procedure date or is planned to occur within 120 days following the index procedure date
  • •Has more than one intracranial aneurysm (IA) that requires treatment within 12 months after the index procedure
  • •Received previous intracranial implant associated with the symptomatic or vascular distribution within the past 84 days prior to treatment date
  • •Chronic anticoagulation therapy is ongoing or known coagulopathy exists
  • •Has atrial fibrillation with or without pacemaker.
  • •Has other known serious concurrent medical conditions such as cardiovascular disease (including recent myocardial infarction [<12 weeks], symptomatic congestive heart failure, or carotid stenosis), kidney failure (>2.0 mg/dl serum creatinine), pulmonary disease, uncontrolled diabetes, progressive neurologic disorders, terminal cancer, vasculitis, high risk of ischemic stroke or recent stroke
  • •Has acute life-threatening illness (e.g., acute kidney or heart failure) other than the neurological disease to be treated in this trial
  • •Evidence of active infection at the time of treatment
  • •Life expectancy is less than 5 years due to other illness or condition (in addition to an intracranial aneurysm)
  • •Unable to comply with the trial follow up requirements due to conditions such as dementia or psychiatric problems, active substance abuse, or history of non-compliance with medical advice, as determined by the investigator
  • •Pregnant or breast- feeding women or women who wish to become pregnant during the length of trial participation
  • •Presence of intracranial mass (tumor, except meningioma, abscess, or other infection), non-treated arteriovenous malformation (AVM) in the territory of the target aneurysm
  • •Enrollment in another study involving an investigational product that could confound the outcomes of this trial

研究组 & 干预措施

Surpass Elite with Guardian Flow Diverter

Experimental

This is a prospective single arm study in which all subjects who present for Surpass Elite with Guardian flow diverter implantation, provide informed consent, and meet inclusion/exclusion criteria may receive treatment.

干预措施: Surpass Elite with Guardian Flow Diverter System (Device)

结局指标

主要结局

The primary efficacy endpoint: Number of subjects with 100% occlusion of the target aneurysm without significant parent artery stenosis, and with no target aneurysm retreatment through the 12-month follow-up visit timepoint.

时间窗: 12 month ± 3 months

The primary efficacy endpoint is a composite of 100% occlusion (Raymond-Roy Class 1, complete occlusion) of the target aneurysm without significant parent artery stenosis (significant parent artery stenosis is defined as \> 50% stenosis, per independent core lab assessment of digital subtraction angiography \[DSA\] images acquired at 12 months \[± 90 days\] post-procedure), and with no target aneurysm retreatment through the 12-month follow-up visit timepoint.

The primary safety endpoint: Number of subjects with neurologic death or major ipsilateral stroke through 12 months as adjudicated by an independent Clinical Events Committee (CEC).

时间窗: 12 month ± 3 months

Neurological death defined as stroke-related death and related to the vascular territory associated with target aneurysm treatment. Major ipsilateral stroke defined as a stroke with an increase in National Institutes of Health Stroke Scale (NIHSS) score ≥ 4 points persisting ≥ 24 hours and related to the vascular territory associated with target aneurysm treatment.

次要结局

  • Secondary Safety Endpoint #1: Number of subjects with neurological death or disabling stroke as adjudicated by an independent Clinical Events Committee (CEC).(12 month ± 3 months, 36 month ± 3 months, and 60 month ± 3 months if FDA grants Premarket approval (PMA) of the Surpass Elite with Guardian Flow Diverter System)
  • Secondary Safety Endpoint #2: Number of subjects with stroke related to the vascular territory associated with target aneurysm treatment as adjudicated by an independent Clinical Events Committee (CEC).(12 month ± 3 months, 36 month ± 3 months, and 60 month ± 3 months if FDA grants Premarket approval (PMA) of the Surpass Elite with Guardian Flow Diverter System)
  • Secondary Safety Endpoint #3: Number of subjects with combined stroke and transient ischemic attack (TIA) events as adjudicated by a CEC(12 month ± 3 months, 36 month ± 3 months, and 60 month ± 3 months if FDA grants Premarket approval (PMA) of the Surpass Elite with Guardian Flow Diverter System)
  • Secondary Efficacy Endpoint #1: Number of subjects with 100% occlusion (Raymond-Roy Class 1, complete occlusion) of the target aneurysm at follow-up visits(12 month ± 3 months, 36 month ± 3 months, and 60 month ± 3 months if FDA grants Premarket approval (PMA) of the Surpass Elite with Guardian Flow Diverter System)
  • Secondary Efficacy Endpoint #2: Number of subjects with 100% occlusion of the target aneurysm at follow-up visits, per independent core lab assessment of any images (including but not limited to MRA and CTA)(12 month ± 3 months, 36 month ± 3 months, and 60 month ± 3 months if FDA grants Premarket approval (PMA) of the Surpass Elite with Guardian Flow Diverter System)
  • Secondary Efficacy Endpoint #3: Number of subjects with significant (> 50% stenosis) parent artery stenosis as determined by independent core lab post-procedure(12 month ± 3 months, 36 month ± 3 months, and 60 month ± 3 months if FDA grants Premarket approval (PMA) of the Surpass Elite with Guardian Flow Diverter System)
  • Secondary Efficacy Endpoint #4: Number of subjects with target aneurysm retreatment.(12 month ± 3 months, 36 month ± 3 months, and 60 month ± 3 months if FDA grants Premarket approval (PMA) of the Surpass Elite with Guardian Flow Diverter System)