Impact of Respiratory Muscle Unloading on Respiratory Muscle Endurance
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 10
- 试验地点
- 2
- 主要终点
- Endurance time
研究概览
简要总结
This study investigates how different degrees of muscular unloading during mechanical ventilation impact endurance of succeeding spontaneous breathing trials
详细描述
Liberation from mechanical ventilation in difficult to wean patients is best accomplished by intermittent spontaneous breathing trials (1). Optimal respiratory muscle rest in-between breathing trials however has never been investigated.
Using a crossover design, patients are to be ventilated with complete and partial respiratory muscle unloading for a period of ten hours respectively. Respiratory muscle activity is being monitored by oesophageal balloon technique using a commercially available System (Avea, Viasys, Conshohocken, PA, USA). Time of spontaneous breathing, respiratory- and ABG parameters are being determined to characterize the course of each spontaneous breathing trial.
References
1. Esteban, A., F. Frutos, M. J. Tobin, I. Alia, J. F. Solsona, I. Valverdu, R. Fernandez, M. A. de la Cal, S. Benito, R. Tomas, and et al. 1995. A comparison of four methods of weaning patients from mechanical ventilation. Spanish Lung Failure Collaborative Group. N Engl J Med 332(6):345-50.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Treatment
- 盲法
- Single
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •hypercapnic respiratory failure
排除标准
- •upper Gi pathology
- •renal failure (creatinin > 2 mg/dl)
- •Sepsis or infection
- •age < 18 years
结局指标
主要结局
Endurance time
次要结局
- PCO2, respiratory parameters