跳至主要内容
临床试验/CTRI/2024/09/074300
CTRI/2024/09/074300已完成4 期

A randomised comparison of LMA proseal, Ambu auragain, baska mask and LMA protector for airway management in laparoscopic surgeries

Ayur Verma1 个研究点 分布在 1 个国家目标入组 120 人开始时间: 2024年10月20日最近更新:

试验速览

阶段
4 期
状态
已完成
发起方
入组人数
120
试验地点
1
主要终点
Oropharyngeal leak pressure

研究概览

简要总结

AIM: A Randomized Comparison of LMA Proseal, Ambu Auragain, Baska Mask and LMA Protector for airway management in laparoscopic surgeries

PRIMARY OBJECTIVE:

§  To compare oropharyngeal leak pressure of LMA Proseal, Ambu Auragain, LMA Protector and Baska mask, when managing airway in laparoscopic surgeries after pneumoperitoneum formation..

 SECONDARY OBJECTIVES:

Following are the secondary objectives-

To compare time taken for insertion of LMA proseal, Ambu Auragain, LMA Protector and Baska mask, when managing airway in laproscopic surgery.

To compare number of attempts of LMA proseal, Ambu Auragain, LMA Protector and Baska mask, when managing airway in laproscopic surgery.

To compare fiber optic view of glottis through LMA proseal, Ambu Auragain, LMA Protector and Baska mask, when managing airway in laproscopic surgery.

To compare the hemodynamic changes which are mean arterial pressure and heart rate at different duration of time which are- a. baseline hemodynamics, b. after induction hemodynamics c. after device placement hemodynamics, and d. after removal hemodynamics.

To compare Ease of SAD insertion of LMA Proseal, Ambu Auragain, LMA Protector and Baska mask, when managing airway in laproscopic surgery.

To compare success rate of insertion of LMA Proseal, Ambu Auragain, LMA Protector and Baska mask, when managing airway in laproscopic surgery.

§  To compare Oropharyngeal leak pressure before pneumoperitoneum formation of LMA Proseal, Ambu Auragain, LMA Protector and Baska mask, when managing airway in laproscopic surgery.

To compare complication (including but not limited to sore throat, blood on device, cough etc) between LMA Proseal, Ambu Auragain, LMA Protector and Baska mask, when managing airway in laproscopic surgery.

To compare saturation at different duration of time which are- a. baseline hemodynamics, b. after induction hemodynamics c. after device placement hemodynamics, and d. after removal hemodynamics.

研究设计

研究类型
Interventional
分配方式
Randomized
盲法
Participant Blinded

入排标准

年龄范围
18.00 Year(s) 至 60.00 Year(s)(—)
性别
All

入选标准

  • ASA physical status 1 and
  • Elective laparoscopic surgeries of anticipated duration less than 2 hours.

排除标准

  • Anticipated difficult airway.
  • Respiratory and cardiovascular disease.
  • Refusal of consent.

结局指标

主要结局

Oropharyngeal leak pressure

时间窗: 20 mins after pneumoperitoneum

次要结局

  • time taken for insertion(immediately after device insertion)
  • Fibreoptic view of glottis(Intraoperatively after confirmation of adequate ventilation)
  • Hemodynamic changes with mean arterial pressure and heart rate.(1. baseline (before induction of anesthesia))
  • ease of insertion(Immediately after device placement)
  • Success rate of insertion(immediately after device insertion)
  • Oropharyngeal leak pressure(after confirmation of correct SAD placement)

研究者

发起方
Ayur Verma
申办方类型
Other [self]
责任方
Principal Investigator
主要研究者

Ayur Verma

King Georges Medical University

研究点 (1)

Loading locations...

相似试验