Changes of Angle Kappa After Implantation of Multifocal Intraocular Lenses

Semmelweis University0 个研究点目标入组 30 人开始时间: 2015年12月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
30
主要终点
Measurement of changes of angle kappa after multifocal intraocular lens implantation.

研究概览

简要总结

The purpose of this study is to evaluate possible changes of angle kappa after multifocal intraocular lens implantation. Presumable influencing factors of postoperative visual axis shift (ie. biometric parameters of the eye) are investigated to determine the degree and direction of angle kappa alterations.

详细描述

The purpose of this study is to evaluate changes of angle kappa after multifocal intraocular lens implantation.

During cataract surgery Medicontur Bi-Flex 677MY IOL and Alcon Acrysof Restor SN6AD1 IOL are implanted. Optical biometry is carried out for IOL calculation and to measure axial length and angle kappa. Three months after surgery biometry is repeated, IOL position and angle kappa are measured using Scheimpflug-camera.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Triple (Care Provider, Investigator, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients with age related cataract and presbyopia

排除标准

  • Patients with previous ocular surgery, trauma, active ocular disease, poorly dilated pupils, or known zonular weakness and corneal astigmatism >1.5 diopters were excluded from the study.

研究组 & 干预措施

Bi-Flex

Active Comparator

Medicontur Bi-Flex 677MY IOL was implanted into 24 eyes of 12 patients during cataract surgery. Angle kappa, biometric data and IOL decantation were measured.

干预措施: cataract surgery (Procedure)

ReStor

Active Comparator

and Alcon Acrysof Restor SN6AD1 IOL was implanted into 36 eyes of 18 patients during cataract surgery. Angle kappa, biometric data and IOL decantation were measured.

干预措施: cataract surgery (Procedure)

结局指标

主要结局

Measurement of changes of angle kappa after multifocal intraocular lens implantation.

时间窗: 3 months

Changes in magnitude and orientation of angle kappa (deviation between the visual and pupillary axis) are measured before and after cataract surgery with multifoocal intraocular lens implantation. During pre-and postoperative examination optical biometry is carried out using Lenstar LS 900. Optical biometer determines deviation between the visual and pupillary axis that represents angle kappa. Deviation of these axes can be defined by its magnitude and orientation. Location of the pupil centre relative to the visual axis - the reference axis - is determined by x- and y-offsets using trigonometrical analysis.

次要结局

  • Determination of influencing effect of biometrical data on postoperative visual axis shift(3 months)
  • Determination of influencing effect of intraocular lens decentration on postoperative visual axis shift(3 months)