NCT05165615Unknown不适用
Comparison of the Two Different Closed-loop Hybrid Systems - AndroidAPS and Control-IQ in Patients With Type 1 Diabetes
Charles University, Czech Republic1 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2020年12月1日最近更新:
适应症
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 20
- 试验地点
- 1
- 主要终点
- Percentage of time in target ranges
研究概览
简要总结
The aim of the investigator's study is to compare two different closed loop hybrid systems - certified Control-IQ and noncertified AndroidAPS in adult patients with Type 1 Diabetes (T1D), who had been using AndroidAPS previously from their own decision, during 12 weeks of follow-up.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Supportive Care
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Type 1 diabetes diagnosed >2 years
- •≥ 18 years old
- •written informed consent prior to starting study related activity
- •previous user of AndroidAPS at least for 3 months
排除标准
- •severe noncompliance
- •lactation, pregnancy, intending to become pregnant during study
- •use of medication with effects on carbohydrate metabolism
结局指标
主要结局
Percentage of time in target ranges
时间窗: Up to 28 weeks
3.9-10.0 mmol/L (70-180 mg/dl)
次要结局
- Changes in glycemic variability(Up to 28 weeks)
- Changes in glycated haemoglobin (HbA1c)(Up to 28 weeks)
- Percentage of time in hypoglycemic ranges(Up to 28 weeks)
- Percentage of time in hyperglycemic ranges(Up to 28 weeks)
- Incidence of severe hypoglycaemia(Up to 28 weeks)
- Diabetes Distress Scale (DDS)(Up to 28 weeks)
- The 5-item World Health Organization well-being index (WHO-5 index)(Up to 28 weeks)
- Hypoglycemia Attitudes and Behavior Scale (HABS)(Up to 28 weeks)
研究者
Jan Soupal, MD
Principal Investigator
Charles University, Czech Republic
研究点 (1)
Loading locations...
相似试验
暂停
1 期
Dose Safety Hybrid Closed Loop and Fully Automated Closed Loop Artificial Pancreas Device in CRCGlucose, Low BloodGlucose, High BloodNCT03428295Dose Safety Inc.20
已完成
不适用
Multi-center Trial in Adult and Pediatric Patients With Type 1 Diabetes Using Hybrid Closed Loop System and Control at HomeType 1 DiabetesNCT02748018Medtronic Diabetes959
尚未招募
不适用
The function and usability of two hybrid closed loop systems in patients aged 13 - 25 years with type 1 diabetes during a 7 day hotel study.Type 1 diabetesACTRN12617001294347princess Margaret Hospital12
进行中(未招募)
不适用
Closed Loop Pumps vs. Traditional Open Loop Pumps in Managing Blood Glucose Levels in T1DM Patients Fasting in Ramadan.Insulin Pump TherapyNCT06416202King Fahad Medical City75
已完成
不适用
FASter Insulin in Closed-loop Technology in ChildrenType 1 Diabetes MellitusNCT04759144University of Cambridge27