Use of a Computerized Body Auscultation Device (©VoqX) for the Diagnosis of Structural Cardiac Pathologies
试验速览
- 阶段
- 不适用
- 状态
- Enrolling By Invitation
- 发起方
- Mayo Clinic
- 入组人数
- 600
- 试验地点
- 2
- 主要终点
- collecting computerized auscultation data in a time-efficient manner at the bedside is feasible
研究概览
简要总结
The purpose of this study is to determine whether recording heart sounds with an acoustic stethoscope, combined with artificial intelligence (computer information), will show similar abnormalities to an echocardiogram or cardiac catheterization.
详细描述
In the current study the plan is to recruit 600 patients who have been referred to the echocardiogram laboratory for routine clinically indicated echocardiography, or to the cardiac catheterization laboratory for routine clinically indicated catheterization procedures. Individuals with normal heart structure and sounds, isolated aortic stenosis (of varying severity), and isolated mitral regurgitation (of varying severity) will be included, while excluding individuals who have multiple valve involvements or combined valve pathologies. Each patient will have baseline testing using the ©CompuSteth device, which will be used to auscultate and record each patient's heart sounds at the bedside prior to the index echocardiogram or cardiac catheterization procedure. This process will take less than 10 minutes and is outlined below. Patients will then proceed with their clinically indicated echocardiograms or cardiac catheterization procedures.
Amongst the first 200 study participants, the results of the echocardiograms and invasive cardiac catheterization procedures will be used to train the ©VoqX device to identify normal heart and to screen and grade for various cardiac structural pathologies, aortic stenosis, and mitral regurgitation, diagnosed by gold-standard testing. Subsequently, after the ©VoqX device has been trained how to characterize and identify sounds that correspond to various structural cardiac pathologies, the next step is to prospectively 'test' how well the ©VoqX device is able to screen normal heart from cardiac pathologies, such as aortic stenosis, and mitral regurgitation, and identify the severity of the valve disorder in the subsequent 200 participants of the study. This will be done by comparing the results obtained from auscultation with the ©VoqX device against the results obtained from gold-standard testing with echocardiography or invasive cardiac catheterization.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- 未提供
排除标准
- 未提供
研究组 & 干预措施
Computerized Auscultation
Patients presenting to the echocardiogram laboratory for routine clinically indicated echocardiography or to the cardiac catheterization laboratory for routine clinically indicated catheterization procedures will undergo a computerized auscultation using the ©VoqX stethoscope and will have their heart sounds auscultated and recorded.
干预措施: ©VoqX stethoscope (Device)
结局指标
主要结局
collecting computerized auscultation data in a time-efficient manner at the bedside is feasible
时间窗: 2 years
i) As part of the initial part of the study, that collecting computerized auscultation data using the ©CompuSteth device from patients presenting to the echocardiogram laboratory for routine clinically indicated echocardiography, or to the cardiac catheterization laboratory for routine clinically indicated catheterization procedures in a time-efficient manner at the bedside is feasible. Further, that we can successfully train the ©CompuSteth device to screen for normal heart structure and sounds as well as for a variety of structural cardiac pathologies, including aortic stenosis and its severity, and mitral regurgitation and its severity, using echocardiography or invasive cardiac catheterization as gold standard testing for the presence or absence of structural cardiac pathologies
次要结局
未报告次要终点