Comparison of Cystoscopic Removal Versus Magnetic Device Removal of Ureteral Stents in Renal Transplant Recipients
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 40
- 试验地点
- 2
- 主要终点
- Feasibility and patient comfort of the retrieval device, using standard validated questionnaire Ureteral Stent Symptom Questionnaire (USSQ)
研究概览
简要总结
This is a pilot, single-centre, feasibility study to assess the feasibility issues and collect preliminary clinical data for the design of future randomized controlled trial to evaluate the feasibility and patient comfort of magnetic retrieval device removal of ureteral stent in transplant patients.
详细描述
To curtail the pain and discomfort during cystoscopic stent removal and in order to improve patient's quality of life, a newly developed ureteral stent with a small magnet at its distal end and a customized magnetic retrieval catheter is recently used in Europe. The product is Black-Star® with a retrieval device by Urotech (Achenmühle, Germany). The magnetic Blackstar stent is a ureteral stent with a small magnet fixed with a string at the distal loop. The placement of stent is similar as routinely done on a guidewire, the only difference is to include the magnetic piece over the guidewire. To remove the stent a customized catheter with a magnetic Tiemann tip is used. The catheter is inserted after urethral application of a standard lubricant and removed with the stent after coming in contact with the stent's magnet.
The stent comes in various sizes and is currently being used in Europe. The studies have concluded fast and easy retrieval of stent without requirement of cystoscopy and decreased patient discomfort.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Prevention
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients at least 18 years of age and capable of giving informed consent
- •Patients scheduled for deceased donor renal transplant surgery
排除标准
- •Patients undergoing Live donor renal transplant
结局指标
主要结局
Feasibility and patient comfort of the retrieval device, using standard validated questionnaire Ureteral Stent Symptom Questionnaire (USSQ)
时间窗: 3-6 weeks
All patients will be followed up 4 weeks post renal transplant surgery, until ureteral stent removal. Feasibility and comfort of stent retrieval, Ureteral Stent Symptom Questionnaire (USSQ) at 4 weeks before stent removal and 1 week post stent removal.
次要结局
- Outcome measure: Cost effectiveness(3-6 weeks)
- Outcome measure: Retrieval time(Baseline (intraoperatively))
- Outcome measure: Infection rate(3-6 weeks)
研究者
Anil Kapoor
Principal Investigator
St. Joseph's Healthcare Hamilton