Prediction of Uncuffed Endotracheal Tube Size in a Pediatric Population by Sonographic Measurements at Various Structures of the Airway Compared to Age-related Formulas and Little-finger Diameters
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 101
- 试验地点
- 1
- 主要终点
- Minimal transverse airway Diameter (MTAD)
研究概览
简要总结
The aim of the present study was to evaluate the ultrasonographic airway measurement in pediatric patients to compare the correct size of an uncuffed endotracheal tube (ETT) with the minimal transverse airway diameter (MTAD) with tube size predicted by different age-related formulas and diameter of little finger.
Previous studies already showed that a prediction of pediatric ETT is possible with the ultrasonographic measurement of the MTAD. In this study measurements are performed at three predefined anatomic structures of the airway with each of These at two airway pressures.
The investigators hypothesize that one of the specific measurements predicts the fitting ETT size better than age-related formulas or diameter of little finger.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Prospective
入排标准
- 年龄范围
- — 至 6 Years(Child)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •signed informed consent by the legal guadian
- •elective surgery requiring endotracheal intubation
排除标准
- •missing informed consent
- •allergy to ultrasound gel
结局指标
主要结局
Minimal transverse airway Diameter (MTAD)
时间窗: Between administration of muscle relaxant and intubation (3min)
In this study measurements of MTAD are performed at three predefined anatomic structures of the airway with each of these at two airway pressures in the time frame between the administration of muscle relaxant and Intubation (average time available 3min).
次要结局
未报告次要终点
研究者
Christoph Schramm, M.D.
Principal Investigator
Heidelberg University