Transcatheter Microguidewire Drilling (TMD) for Transseptal Left Atrial Access: First-in-human Use Study
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 100
- 试验地点
- 2
- 主要终点
- Procedural Success
研究概览
简要总结
This study aims to investigate the safety and efficacy of transcatheter microguidewire drilling (TMD) for transseptal left atrial access in patients with abnormal atrial septal morphology.
详细描述
Despite the widespread application and decades of experience, Brockenbrough-needle transseptal puncture still risks cardiac perforations and secondary pericardial effusion/tamponade, especially in patients with abnormal atrial septal morphology. To facilitate atrial septal crossing, different methods and devices have been developed, including radiofrequency energy, excimer laser, SafeSept wire and so on. However, these are still limited by availability and cost, and the advantages might be further offset by the potential risks. In addition, these methods are performed mainly with the linear insertion technique, which might result in less forward-force to penetrate atrial septum and displacement of needle-tip. Therefore, it is necessary to develop a safe, available and low-cost transseptal procedure for these patients.
Through a Brockenbrough needle, the hard "back-end" of the microguidewire (0.014-inch) has the potential to drill through the atrial septum with ease. Compared with a standard linear insertion technique, the penetration might be improved and less force is required with the bidirectional rotation technique, and the related risks might be reduced with the modified TSP due to the thin microguidewire. After the passage of the needle, the soft-end of microguidewire can be introduced into left pulmonary superior vein, which can become a safe rail for the introduction of puncture dilator/sheath.
In this study, we examined the effectiveness and safety of microguidewire-assisted TSP for patients with complex atrial septum.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Single (Participant)
入排标准
- 年龄范围
- 3 Years 至 99 Years(Child, Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients with atrial septal aneurysm (a bulging of the atrial septum of at least 10 mm beyond the plane of the atrial septum into either the right or left atrium); 2) Or patients with previous multiple transseptal punctures (≧2); 3) Or patients with thickened atrial septum (thickness ≧3 mm); 4) Or patients with enlarged right atrium (≧ 6 cm) and diminished left atrium (< 3 cm); 5) Or patients with prior mitral valve surgery; 6) Or patients with atrial baffles.
排除标准
- •Associated atrial septal defect or patent foramen ovale; 2) Associated interrupted inferior vena cava; 3) Presence of implanted cardiac devices; 4) Echocardiographic evidence of intracardiac thrombus, mass, tumor or vegetation; 5) Thromboembolic events within the last 6 months; 6) Patients unable to grant informed, written consent.
研究组 & 干预措施
Conventional transseptal puncture
Under the guidance of fluoroscopy and echocardiography, transseptal puncture was performed with Brockenbrough-needle.
干预措施: Transseptal puncture with Brockenbrough-needle (Device)
Microguidewire-assisted transseptal puncture
The Brockenbrough needle, with transseptal dilator and sheath, was introduced into the right atrium and engaged in the fossa ovalis, which was confirmed with angiographical and echocardiographical "tenting sign". 1) the hard-end of a 0.014-inch microguidewire drilled through atrial septum through Brockenbrough-needle; 2) then the needle was advanced into left atrium over the fixed microguidewire; 3) finally the soft-end of microguidewire was introduced into left atrium/left superior pulmonary vein through Brockenbrough-needle, which was further advanced over the fixed microguidewire.
干预措施: Microguidewire-assisted transseptal puncture (Device)
结局指标
主要结局
Procedural Success
时间窗: 1 Day of procedure
Number of participants with successful transseptal left atrial access
Related-complications
时间窗: 1 Day of procedure
Pericardial effusion
次要结局
- Transseptal Access Procedure Time(1 Day of procedure)