跳至主要内容
临床试验/NCT04060563
NCT04060563终止不适用

Frequency Specific Microcurrent for the Treatment of Diastasis Recti

Diana Trang2 个研究点 分布在 1 个国家目标入组 13 人开始时间: 2020年1月1日最近更新:
适应症

试验速览

阶段
不适用
状态
终止
发起方
入组人数
13
试验地点
2
主要终点
Inter-rectus Distances (IRD)

研究概览

简要总结

Determine if frequency specific microcurrent therapy improves pain management of DRA by 30% or greater.

详细描述

Females aged 18 years or older who are postpartum from a singleton gestation status post vaginal and with diastasis recti will be recruited. The aim of this study is to determine if frequency specific microcurrent therapy improves pain management of DRA by 30% or greater

Improving DRA after microcurrent therapy in post-partum females may allow a faster, more effective return to activity thereby improving the return-to-duty transition and establishing personal readiness by meeting military fitness standards.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • **Patients must be able to get care at Nellis Air Force Base (a military installation) in order to participate in this study**
  • Inclusion Criteria:
  • Active Duty and DoD beneficiary Postpartum Females (12 hours to 24 hours) with Diastasis Rectus Abdominus (DRA) pain
  • Aged 18 years or older
  • Singleton gestation/delivered (one baby carried and born)
  • Vaginal delivery
  • Nulliparous (first pregnancy) or multiparous (more than one pregnancy in the past)

排除标准

  • less than 18 years of age
  • females greater than 24 hours post-partum
  • Medical history to include pacemaker
  • History of arrhythmia
  • Transplant status
  • Insulin pump
  • Pain pump
  • Active cancer
  • Inability to measure IRD
  • Delivery via caesarean section
  • Operative vaginal delivery (vacuum or forceps)
  • 3rd or 4th degree vaginal laceration

结局指标

主要结局

Inter-rectus Distances (IRD)

时间窗: visit 3/week 3

Investigator will apply ultrasound gel and measure Inter-rectus distances (IRD) -- via ultrasound or if unable via ultrasound, via palpation and measuring tape -- taken at 4 locations using the medial margins of both rectus abdominis muscles: A. 2.5 cm above the umbilical ring, B. upper margin of the umbilical ring, C. lower margin of the umbilical ring, and D. 2.5 cm below the umbilical ring. A and D were recorded.

次要结局

未报告次要终点

研究者

发起方
Diana Trang
申办方类型
Fed
责任方
Sponsor Investigator
主要研究者

Diana Trang

Principal Investigator

Mike O'Callaghan Military Hospital

研究点 (2)

Loading locations...

相似试验