跳至主要内容
临床试验/NCT01168453
NCT01168453已完成不适用

Changes in the Relationship Between the Right Internal Jugular Vein and Anatomical Landmark After Head Rotation

Soonchunhyang University Hospital1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2009年5月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
100
试验地点
1
主要终点
anatomical landmark point (AL) - ultrasonography point (US) distance(the distances from the AL point to the US point )

研究概览

简要总结

This study was performed to ultrasonographically demonstrate the changes in relationship between the right internal jugular vein (IJV) and an anatomical landmark in two different head positions: neutral and rotational.

详细描述

Background: This study was performed to ultrasonographically demonstrate the changes in relationship between the right IJV and an anatomical landmark in two different head positions: neutral and rotational.

Methods: One hundred patients scheduled for elective surgery under general anesthesia with endotracheal intubation were enrolled in this study. The patients were placed in the supine position with a neutral head position and without a pillow. The apex of the triangle formed by the sternal and clavicular heads of the sternocleidomastoid muscle and clavicle was marked (anatomical landmark point: AL point). The ultrasonography of the neck anatomy was performed, and a mark was placed at the central point of the IJV to the skin (ultrasonography point: US point). The other investigator measured the distances from the AL point to the US point (AL-US distance). The patient's head was then turned 30° to the left; the same procedure was repeated and the AL-US distance was again measured. The changes in AL-US distance were calculated.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 100 patients weighing 40 - 100 kg and with heights of 140 - 190 cm

排除标准

  • a history of neck surgery or trauma involving the neck, previous IJV-related interventions (e.g., venous catheterization), limitation of neck movement, and a body mass index ≥ 30.

结局指标

主要结局

anatomical landmark point (AL) - ultrasonography point (US) distance(the distances from the AL point to the US point )

时间窗: within 5 minutes after itubation

The distance between the two points was considered "positive" if the US point was lateral to the AL point and "negative" if it was medial to the AL point.

次要结局

  • The average depth of the right IJV(within 5 minutes after intubation)

研究者

申办方类型
Other

研究点 (1)

Loading locations...