临床试验/NCT03795935
NCT03795935Unknown不适用

Relief From Side Effects: Clinical Use of Electrodes With Direction: a Prospective, Open Label, Clinical Trial for Thalamic Deep Brain Stimulation

University of British Columbia2 个研究点 分布在 1 个国家目标入组 6 人开始时间: 2018年9月17日最近更新:
适应症
干预措施

试验速览

阶段
不适用
入组人数
6
试验地点
2
主要终点
Tremor Control

研究概览

简要总结

Deep Brain Stimulation (DBS) uses electrical pulses sent through a lead (insulated wire) to help stop unwanted symptoms in a variety of brain diseases, including the tremor seen in patients with Essential Tremor (ET). The current standard lead allows this stimulation to spread out uniformly in all directions. As these diseases progress, however, the amount of electrical stimulation required to stop the symptom usually increases. This may become problematic because the increased electrical stimulation required for advanced symptoms may spread outside the desired targeted area, and effect other parts of the brain and causing unwanted side effects. A new type of DBS lead has been developed which can steer, or focus, the electrical stimulation in a given direction toward the desired target area and away from areas that would cause side effects. We would like to quantify the benefit seen in patients who have been switched from the traditional lead to this new directional lead.

详细描述

Patients implanted with a DBS may experience unwanted side effects such as motor contractures, paresthesia, or dysarthria. This occurs when the electrical field of the stimulation spreads out beyond the targeted area. This is especially common in patients whose disease has progressed, and must use increasingly higher currents in order to regain control of their tremor. Unfortunately, because the electrical field affects neurons in a symmetrical sphere around the DBS, it is often impossible to reach the additional desired neuronal elements without simultaneously affecting equidistant brain regions responsible for side effects. For many of our advanced patients, this means choosing between a debilitating tremor or disabling side effects.The directional lead is a FDA and Health Canada approved DBS lead which features radially segmented electrodes which can selectively steer the electrical field in a predefined direction, orthogonal to the lead trajectory. This will allow DBS clinicians to steer current towards desired structural areas, while avoiding locations, which produce negative side effects.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Participants must have been implanted with the DBS
  • Participants must have been diagnosed with Essential Tremor
  • Participants must experience negative side effects from their DBS which limit control over their tremor
  • Participants must be able to receive benefit from their stimulator, but at the cost of negative side effects

排除标准

  • All individuals who meet criteria outlined in "inclusion criteria" may be eligible for this study

研究组 & 干预措施

Treatment

Experimental

Patients who were previously implanted with a traditional DBS lead and have subsequently developed stimulation induced side effects will gain significantly more tremor control without side effects when re-implanted with a directional DBS lead. We expect these patients' quality of life will improve. These patients typically will have had significant tremor relief (greater than 75% reduction from preoperative tremor rating scale) without side effects at their one year post operative follow-up. With the expected disease progression they will have had to increase their DBS stimulation to the degree that their DBS now causes side effects in order to block their tremor

干预措施: No side-effect stimulator settings with directional lead (Other)

结局指标

主要结局

Tremor Control

时间窗: Assessed once all tests performed - 1 to 2 months post-operatively

Maximum percentage change in tremor (as measured by the Tremor Rating Scale) without side-effects (comparing DBS "on" versus "off") in each patient using the standard lead compared to the directional lead.

次要结局

  • Quality of life based on voice handicap with participant's best real life setting(Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured)
  • Quality of life based on participant's best real life setting(Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured)
  • Quality of life based on tremor management participant's best real life setting(Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Christopher Honey

Neurosurgeon, Professor of Surgery (Neurosurgery), Director of Surgical Centre for Movement Disorders

University of British Columbia