跳至主要内容
临床试验/NCT02851927
NCT02851927已完成不适用

Rigid 'Mini-thoracoscopy' vs Semirigid Thoracoscopy in Undiagnosed Exudative Pleural Effusions : A Randomized Controlled Trial

All India Institute of Medical Sciences, New Delhi2 个研究点 分布在 1 个国家目标入组 73 人开始时间: 2016年6月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
73
试验地点
2
主要终点
Diagnostic Yield

研究概览

简要总结

Undiagnosed pleural effusion is a diagnostic dilemma especially in exudative pleural effusions (EPE). 20-40 % are unable to be attributed to a specific diagnosis, even after thoracentesis and closed pleural biopsy. Thoracoscopy has been demonstrated to increase the diagnostic yield in undiagnosed EPE. The diagnostic yield of thoracoscopy in malignant and TB pleural effusion ranges from 91% to 94% and 93% to 100%, respectively.

Rigid thoracoscopy has traditionally been the modality of choice. The recently introduced semirigid thoracoscope provides ease of handling like a flexible bronchoscope. However, there are concerns about the diagnostic yield of semi-rigid thoracoscopy when compared with rigid thoracoscopy. According to the available literature, the yield of semirigid and rigid thoracoscopy is almost similar if adequate pleural biopsy is obtained. However there are concerns that with semi-rigid thoracoscope, there might be greater incidence of inability to obtain adequate pleural biopsy. On the other hand, the use of conventional rigid thoracoscope may be associated with greater procedure related pain.Mini-Thoracoscopy is a newer rigid thoracoscopy instrument which is smaller in diameter (5.5 mm) and may allow pleural biopsy with a smaller incision. There is scant literature on its utility. The investigators hereby propose to undertake a randomized comparison of rigid 'mini thoracoscope' vs semi rigid thoracoscope in undiagnosed pleural effusions.

详细描述

Patients meeting the inclusion criteria and giving prior consent for the study shall be randomised. The randomization sequence will be computer generated with variable block size and the assignments will be placed in opaque sealed envelopes. All patients will undergo hemogram, liver and renal function tests, coagulation profile, an electrocardiogram and Computed tomography (CT) of the chest before entering the study. Chest ultrasound will be performed in all patients to evaluate the rib spaces, amount of pleural fluid and for selection of the entry point.

Instruments The semi-rigid thoracoscope to be used is the autoclavable Olympus LTF-160 (Olympus, Tokyo, Japan) thoracoscope with 2.8 mm inner channel diameter and 7 mm outer diameter. The forceps is flexible forceps with alligator jaw with spike cusps, 2.8 mm of the outer diameter. The rigid mini thoracoscope is the Richard Wolf 5.5 mm operating endoscope with the working channel.

Thoracoscopy technique Thoracoscopy will be performed in the interventional pulmonology lab. Patients shall be fasting for solids for 8 hours and for liquids 6 hours. Patients shall be having continuous monitoring of blood pressure, pulse rate, and oxygen saturation.

Topical anesthesia will be achieved by infiltrating 2% lidocaine locally at the incision site. The procedure shall be performed under conscious sedation and analgesia using a combination of midazolam and intravenous fentanyl. An incision shall be made at the site of maximum fluid thickness as assessed by pre-procedural USG chest, with the patient in lateral decubitus position and involved side upward. After incision, the appropriately sized trocar shall be placed through the skin into the pleural space. The thoracoscope shall be inserted through the trocar. The pleural surfaces shall then be thoroughly inspected. A minimum of 6-8 pleural biopsy samples shall be obtained by semi-rigid thoracoscope and at least 4 with rigid mini-thoracoscope.

Samples shall be sent for histopathological analysis and mycobacterial cultures. At the end of the procedure, a chest tube shall be placed and removed subsequently.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age >18 years Presence of undiagnosed exudative pleural effusion as determined by the criteria detailed by Light et al where a specific diagnosis was not obtained after initial cytological and/or microbiological examinations.
  • Adequate rib spaces for successful performance of thoracoscopy as judged by clinical examination Adequate pleural fluid space as judged by pre-procedural USG chest

排除标准

  • Coagulopathy (platelet count < 50000/mm3, INR > 1.5)
  • Unstable hemodynamic status ( SBP > 180, DBP> 100 or SBP< 90 mm Hg / heart failure
  • Myocardial infarction or unstable angina in the last 6 wk
  • Hypoxemia not correctable with low flow oxygen (SpO2 <90% despite low flow oxygen @ 1-2 l/min)
  • Extensive rib crowding as judged by clinical examination
  • Extensive adhesions and lack of pleural space on USG chest
  • Refusal of consent

研究组 & 干预措施

Mini Thoracoscopy

Experimental

Thoracoscopy procedure shall be performed using the Rigid Mini Thoracoscope

干预措施: Mini Thoracoscopy (Procedure)

Semirigid Thoracoscopy

Active Comparator

Thoracoscopy procedure shall be performed using the SemiRigid Thoracoscope

干预措施: SemiRigid Thoracoscopy (Procedure)

结局指标

主要结局

Diagnostic Yield

时间窗: Through study completion, an average of 1 year

Proportion of diagnostic biopsies in the two arms

次要结局

  • Biopsy Size(Through study completion, an average of 1 year)
  • Image quality(Through study completion, an average of 1 year)
  • Sedation dose(Through study completion, an average of 1 year)
  • Complications(Through study completion, an average of 1 year)
  • Operator rated pain(Through study completion, an average of 1 year)
  • Operator rated overall procedure satisfaction(Through study completion, an average of 1 year)
  • Procedural pain(Through study completion, an average of 1 year)
  • Alternate equipment(Through study completion, an average of 1 year)

研究者

发起方
All India Institute of Medical Sciences, New Delhi
申办方类型
Other
责任方
Principal Investigator
主要研究者

Karan Madan

Dr Karan Madan MD, DM Assistant Professor

All India Institute of Medical Sciences, New Delhi

研究点 (2)

Loading locations...

相似试验