跳至主要内容
临床试验/NCT05508711
NCT05508711已完成不适用

Comparability of Transesophageal Echocardiography and Continuous Mini-invasive FloTrac/Vigileo System (© Edwards Lifesciences) for the Determination of Cardiac Output in Three Different Positions During General Anesthesia

Université Libre de Bruxelles1 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2021年10月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
40
试验地点
1
主要终点
To verify the FloTrac/Vigileo's ability to estimate cardiac output (L/min) in Trendelenburg position.

研究概览

简要总结

The use of cardiac output monitoring to guide intraoperative fluid management and inotropic drugs as part of a hemodynamic therapy algorithm reduce the complication rate in major abdominal surgery. The FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device estimate cardiac output by using arterial pulse contour analysis. The accuracy of FloTrac/Vigileo have been proven in patients with normal cardiac index. Most of studies regarding FloTrac/Vigileo were performed in patients in horizontal supine position, which is not usually the reality in the operation theater during abdominal surgery. Therefore, the investigators realized this monocentric prospective clinical trial to study the accuracy and trending ability of the fourth generation FloTrac/Vigileo system cardiac output estimation in three different positions (horizontal supine, Trendelenburg and reverse Trendelenburg positions) in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output measurement used was the transesophageal echocardiography.

研究设计

研究类型
Observational
观察模型
Other
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • patients scheduled for elective pancreatic, bladder or liver surgery requiring invasive monitoring and Trendelenburg position during the procedure

排除标准

  • age under 18 years
  • weight under 40 kg
  • preoperative left ventricular ejection fraction (LVEF) less than 45%
  • severe heart valve disease
  • known intra-and/or extracardiac shunt
  • pulmonary hypertension
  • preoperative circulatory shock with need for hemodynamic inotropic support
  • redo surgery
  • pregnancy

结局指标

主要结局

To verify the FloTrac/Vigileo's ability to estimate cardiac output (L/min) in Trendelenburg position.

时间窗: Baseline

To study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in Trendelenburg position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.

To verify the FloTrac/Vigileo's ability to estimate cardiac output (L/min) in horizontal supine position.

时间窗: Baseline

To study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in horizontal supine position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.

To verify the FloTrac/Vigileo's ability to estimate cardiac output (L/min) in reverse Trendelenburg position.

时间窗: Baseline

To study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in reverse Trendelenburg position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Lucelia Fernandes Ricciardi

Principal Investigator

Université Libre de Bruxelles

研究点 (1)

Loading locations...

相似试验