Cholangiocarcinoma Detection Using an Intraoperative Fluorescence Image Guided Approach With Bevacizumab-IRDye 800CW
试验速览
- 阶段
- 1 期
- 入组人数
- 12
- 试验地点
- 1
- 主要终点
- Optimal dose finding of Bevacizumab 800CW in hilar cholangiocarcinoma
研究概览
简要总结
Cholangiocarcinoma is an epithelial cell malignancy arising from varying locations within the biliary tree and is difficult to diagnose due to the often-silent clinical nature. The best chance of long-term survival and potential cure is surgical resection with negative surgical margins, but many patients are unresectable due to locally advanced or metastatic disease at diagnosis. Because cholangiocarcinoma is difficult to diagnose at an early stage and extends diffusely, most patients have unresectable disease at clinical presentation, and prognosis is very poor (5-year survival is 0-40% even in resected cases)
There is a need for better visualization of tumor tissue, lymph nodes and resection margins during surgery for perihilar cholangiocarcinoma (PHCC). Optical molecular imaging of PHCC associated biomarkers is a promising technique to accommodate this need. The biomarkers Vascular Endothelial Growth Factor (VEGF-A), Epidermal Growth Factor Receptor (EGFR) and c-MET are all overexpressed in PHCC versus normal tissue and are proven to be valid targets for molecular imaging. Currently, tracers that target these biomarkers are available for use in clinical studies. In previous studies with other tumor types, the investigators tested the tracer bevacizumab-IRDye800CW for the biomarker VEGF-A with very promising results. Since all markers show roughly similar expression in ex vivo studies, the initial study will be performed with bevacizumab-IRDye800CW as the investigators have the most experience with this tracer. The investigators hypothesize that the tracer bevacizumab-IRDye 800CW accumulates in PHCC tissue, enabling visualization using a NIR intraoperative camera system and ex vivo NIR endoscopy. In this pilot study, the investigators will determine if it is possible to detect PHCC intraoperatively and by ex vivo NIR endoscopy using bevacizumab 800CW, and which tracer dose gives the best target-to-background ratio. The most optimal tracer dose will be selected for a future phase II trial.
详细描述
See brief summary
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients with clinical suspicion of PHCC who are scheduled to undergo surgical intervention with curative intent
- •WHO performance score 0-2.
排除标准
- •Medical or psychiatric conditions that compromise the patient's ability to give informed consent.
- •Other invasive malignancy
- •Pregnant or lactating women.
- •History of infusion reactions to bevacizumab or other monoclonal antibody therapies.
- •Inadequately controlled hypertension with or without current antihypertensive medications
- •Within 6 months prior to inclusion: myocardial infarction, TIA, CVA pulmonary embolism, uncontrolled chronic hepatic failure, unstable angina pectoris.
研究组 & 干预措施
Intraoperative NIR fluorescence imaging
A non-randomized, non-blinded, prospective, single center pilot dose escalation study with bevacizumab-800CW for NIR fluorescence image guided surgery in hilar cholangiocarcinoma
- IV-administration of 10, 25 or 50 mg of the fluorescent tracer bevacizumab-800CW to a total of 15 patients with resectable hilar cholangiocarcinoma 3 days prior to surgery.
- Peroperative open air NIR fluorescence imaging
- Ex vivo endoscopic and histopathological NIR fluorescence imaging
干预措施: Bevacizumab-IRDye800CW (Drug)
Intraoperative NIR fluorescence imaging
A non-randomized, non-blinded, prospective, single center pilot dose escalation study with bevacizumab-800CW for NIR fluorescence image guided surgery in hilar cholangiocarcinoma
- IV-administration of 10, 25 or 50 mg of the fluorescent tracer bevacizumab-800CW to a total of 15 patients with resectable hilar cholangiocarcinoma 3 days prior to surgery.
- Peroperative open air NIR fluorescence imaging
- Ex vivo endoscopic and histopathological NIR fluorescence imaging
干预措施: near infrared (NIR) fluorescence imaging (Device)
结局指标
主要结局
Optimal dose finding of Bevacizumab 800CW in hilar cholangiocarcinoma
时间窗: 24 months
- Comparison of three doses of Bevacizumab 800CW by calculating target to background ratios in fluorescence images obtained during and directly after the surgical procedure and fluorescence images obtained during ex vivo analyses in bread loaf slices and in histological slices (odyssey scanner, fluorescence microscopy).
次要结局
- Peroperative detection of hilar cholangiocarcinoma with real-time near-infrared fluorescence camera(24 months)
- Detection of hilar cholangiocarcinoma in real-time near-infrared fluorescence ex-vivo endoscopy(24 months)
- Establish tracer distribution in tumour tissue(24 months)
- Measurement of fluorescence in tumour tissue en surrounding normal tissue(24 months)
研究者
dr. W.B. Nagengast, MD
Dr. W.B. Nagengast, Gastroenterologist, Principal Investigator
University Medical Center Groningen
