跳至主要内容
临床试验/NCT06073587
NCT06073587已完成不适用

CARDIO-TTRansform ION-682884-CS2-Scintigraphy Sub-study

Ionis Pharmaceuticals, Inc.10 个研究点 分布在 2 个国家目标入组 163 人开始时间: 2023年4月4日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
163
试验地点
10
主要终点
Changes From Baseline in Perugini Grading Score From Scintigraphy Scan Images at Week 140

研究概览

简要总结

The purpose of this study is to examine the changes in amyloid myocardial burden in a subset of the population participating in the ION682884-CS2 (NCT04136171) study, up to 150 participants, after treatment with eplontersen or placebo based on scintigraphy scans performed at Week 140 using the Perugini grade score method.

详细描述

Participants who were randomized in Study ION-682884-CS2 (NCT04136171) and have had a baseline scintigraphy scan will be offered the opportunity to participate in this sub-study which involves optional scintigraphy scans.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Participants must have been properly randomized into the ION-682884-CS2 study (NCT04136171) and should have had a baseline scintigraphy scan (99mTc-DPD, 99mTc- PYP, and 99mTc-HMDP) within 12 months prior to screening for ION-682884-CS2 with planar and SPECT or SPECT/CT images that can be read by the central reader.

排除标准

  • Must not meet any of the exclusion criteria of the study protocol ION-682884-CS2 (NCT04136171).
  • Must not have weight or body girth that exceeds the limits of the equipment specifications.
  • Should not have any previously reported hypersensitivity reaction to Technetium-99m.

研究组 & 干预措施

ION-682884-CS2 Scintigraphy Subset

Participants randomized in ION-682884-CS2 (NCT04136171) study to receive either eplontersen or placebo with baseline scintigraphy scan with planar and single-photon emission computerized tomography (SPECT) or SPECT with computed tomography (SPECT/CT) images will undergo an optional scintigraphy scan at Weeks 25 or 37, Week 97, and an additional scan at Week 140.

干预措施: Scintigraphy scan (Diagnostic Test)

结局指标

主要结局

Changes From Baseline in Perugini Grading Score From Scintigraphy Scan Images at Week 140

时间窗: Baseline up to Week 140

The Perugini grading scale visually compares tracer uptake in the myocardium and ribs following injection of the bone tracers (99mTc-DPD, 99mTc-Pyrophosphate \[PYP\], or 99mTc-HMDP). The scale includes 4 grade classifications: Grade 0- no cardiac uptake and normal rib uptake, Grade 1- cardiac uptake which is less than rib uptake, Grade 2- cardiac uptake with intensity similar rib uptake, and Grade 3- cardiac uptake greater than rib uptake with mild or absent rib uptake. Visual scores of 2 or greater are classified as ATTR-positive and less than 2 are interpreted as ATTR-negative.