跳至主要内容
临床试验/NCT05467488
NCT05467488已完成不适用

Ultraviolet A and Ultraviolet C Light-induced Effects on Dental Implant Stability

Prof. Abdul Mueed Zaigham1 个研究点 分布在 1 个国家目标入组 66 人开始时间: 2017年6月15日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
66
试验地点
1
主要终点
ISQ measurement through Ostelltm Mentor device

研究概览

简要总结

Until now, limited research has observed the stability of photo functionalized sandblasted acid-etched (SLA) titanium implants. The study includes a sample size of sixty otherwise healthy patients with implant replacement, comparing nonirradiated, irradiated UVA and UVC titanium implants. It was an interventional study with a sample size divided into three groups using simple randomization. Patients with nonirradiated dental implants make the control group A with UVA and UVC dental implants forming groups B and C, respectively. Before functional loading, implant stability was measured on days zero and eight weeks. SPSS 26.0 is used for data analysis. The data for implant stability quotient (ISQ) levels and osseointegration speed index (OSI) were presented as mean ± SD for each group. The effect of UVA and UVC on ISQ2 compared with the baseline ISQ was done by applying multiple simple regression analysis models, whereas the distinction between UVA and UVC was made through a t-test. p ≤ 0.05 was kept statistically significant. The implants irradiated with UVA significantly affected ISQ levels compared to other groups.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
21 Years 至 60 Years(Adult)
性别
All
接受健康志愿者
是

入选标准

  • •systemically healthy patients with age > 20 with at least one tooth or more missing

排除标准

  • 未提供

研究组 & 干预措施

Non irradiated implants (group A)

No Intervention

UVA irradiated group (group B)

Active Comparator

干预措施: photofunctionalization (Procedure)

UVC irradiated group (group C)

Active Comparator

干预措施: photofunctionalization (Procedure)

结局指标

主要结局

ISQ measurement through Ostelltm Mentor device

时间窗: eight months

The Ostelltm device was initially calibrated using a test peg called the ISQ. A smart peg was used for assessment. The smart peg tightened with 5 Ncm torque is then mounted on implant fixture and the transducer connected perpendicular to the implant . The measuring probe is brought closer to the smart peg without touching it. A beeping sound displays the reading on the monitor. Two successive readings are taken mesiodistally along the jaw and buccolingually perpendicular to the jaw .The RFA measurements taken twice during implant treatment are recorded. All the ISQ values were recorded from one to hundred and a mean was taken.

次要结局

未报告次要终点

研究者

发起方
Prof. Abdul Mueed Zaigham
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Prof. Abdul Mueed Zaigham

Professor

CMH Lahore Medical And Dental College

研究点 (1)

Loading locations...