Distance And Intermediate Visual Acuity After Phacoemulsification Using A New Generation Monofocal Intraocular Lens Compared To Standard Monofocal Intraocular Lens
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 20
- 试验地点
- 2
- 主要终点
- Uncorrected and best-corrected distance, and intermediate visual acuity.
研究概览
简要总结
This is a prospective comparative interventional clinical study, that took place from January 2021 to November 2021. Twenty patients (20) were enrolled in this study 10 patients in each group. It was designed for comparison of uncorrected and best corrected distance and intermediate vision in patients whom implanted with monofocal Tecnis Eyhance or Tecnis 1-piece IOLs.
详细描述
Purpose To determine the Uncorrected and best-corrected distance, and intermediate visual acuity in a new innovative monofocal intraocular lens compared with standard monofocal lens.
Methods This is a prospective comparative interventional clinical study, that took place from January 2021 to November 2021. 40 eyes of Twenty patients (20) were enrolled in this study, patients who are candidates for cataract extraction by phacoemulsification were included in this study and underwent thorough preoperative examination and post-operative evaluation at 3 months after the 2nd eye operation, of distance, intermediate, near add, contrast sensitivity and incidence of photic phenomena using a printed questionnaire for evaluating this incidence and binocular defocus curves were analyzed.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Parallel
- 主要目的
- Health Services Research
- 盲法
- None
入排标准
- 年龄范围
- 50 Years 至 75 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Patients aged 50-75 years old undergoing cataract surgery.
- •Preoperative corneal astigmatism equal to or less than - 1.00 D.
- •Availability, willingness and sufficient cognitive awareness to comply with examination procedures
排除标准
- •Visual potential of less than 0.63 due to ocular pathologies.
- •Corneal astigmatism over -1.00 D cylinder.
- •Pupil abnormalities (non-reactive, tonic pupils, abnormally shaped pupils, or pupils that do not dilate at least 3.5 mm under mesopic/scotopic conditions).
- •Capsule or zonular abnormalities that would affect postoperative centration or tilt of the lens and pseudoexfoliation syndrome.
- •Macular degeneration, cystoid macular edema,Diabetic retinopathy, history of uveitis, optic nerve diseases, glaucoma and amblyopia.
结局指标
主要结局
Uncorrected and best-corrected distance, and intermediate visual acuity.
时间窗: 3 months post operative
Distance visual acuities were examined by ETDRS chart and intermediate and near visual acuity by Jaeger chart at 66 cm and 33 cm respectively.Measured values of the visual acuity were expressed in decimal values and converted to logMAR values.
次要结局
- Contrast sensitivity(3 months post operative)
研究者
Rokaya Emad Radwan
ophthalmology resident
Kasr El Aini Hospital