3T Perfluorocarbon-Filled Endorectal Magnetic Resonance Spectroscopic Imaging of Prostate
试验速览
- 阶段
- 不适用
- 状态
- 终止
- 入组人数
- 90
- 试验地点
- 2
- 主要终点
- Comparison of linewidths collected from AIR MRSI and PFC-MSRI
研究概览
简要总结
Objectives:
The objectives of this study are to: 1) evaluate the feasibility of 3T MRSI of prostate in improving the spectral resolution, using a PFC-filled endorectal coil, 2) develop a systematic metabolic grading system for tumor detection by identifying the abnormal peak areas of Cho, Cr, Po, and Ci for the prostate carcinoma, specifically from PFC-filled endorectal 3T MRSI, and 3) evaluate the efficacy of the metabolic grading system in tumor detection.
The long-term goal of the study is to provide an early prognostic indicator and means of monitoring the biologic status of the prostate cancer during the course of the disease.
详细描述
Part 1:
Prostate cancer tissue has certain differences in its metabolism (chemical makeup) that are not seen in normal tissue. MRSI is a type of magnetic resonance imaging (MRI) that uses the same type of scanner as a standard MRI. Unlike standard MRI, which takes pictures of the body regions, MRSI shows the metabolic features of the prostate cells. MRSI exams that use a "coil" behind the prostate (inside of the rectum) have been used to measure the metabolic features of prostate cancer tissue. This has been shown to improve the accuracy of finding prostate tumor using standard scanners called "1.5T" scanners.
The coil works like an antenna, and air is normally used inside the coil to inflate it. The accuracy of endorectal MRSI exams still needs improvement. Use of PFC instead of air inside of the coil has been shown to greatly improve the quality of MRSI images at 1.5T scanners. At first, researchers want to learn if the newer, stronger (3T) scanners will improve the quality of endorectal MRSI exam when combined with PFC within the coil. PFC is a clear and odorless liquid that, as opposed to air, is physically very similar to human tissue (such as prostate tissue). This makes the MRSI images much clearer.
If you agree to take part in this study (Part 1) and are found to be eligible, you will have 2 MRSI exams (one with air and one with PFC) using an endorectal coil.
Before being inserted, the coil will be inflated with air to check for a possible leak. You will lie on one side, inside of a 3T MRI scanner, and the coil (covered with protective nonlatex or latex) will be inserted into your rectum. Having the coil inserted is similar to having an enema tip inserted. The coil will be filled with air, and you will lie on your back so the first MRSI exam can be completed. Once the first MRSI exam is completed, as much of the air as possible will be removed from the coil using a syringe.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- Male
- 接受健康志愿者
- 否
入选标准
- •Biopsy proven, clinical stage 1-3 prostate carcinomas
- •Prostatectomy at M. D. Anderson within 3 months from the time of MRSI
- •An interval of > 6 weeks between the biopsy and MRSI
- •Signed informed consent form
排除标准
- •Contraindications for MRI (e.g. cardiac pacemaker)
- •Contraindications for MRS (e.g. history of abdomino-perineal resection of rectum)
- •Metals or any conditions (e.g. hip prosthesis) that can distort the local magnetic field
- •Previous prostate surgery for prostate carcinoma (including, TURP and cryosurgery), local or systemic treatment for prostate carcinoma (e.g. radiation, androgen deprivation), pelvic radiation (e.g. rectal cancer), rectal surgery, BCG for bladder cancer
结局指标
主要结局
Comparison of linewidths collected from AIR MRSI and PFC-MSRI
时间窗: 2 MRSI studies should take about 60 minutes; study participation completed with prostatectomy to take place within 3 months of MRSI exams
The outcome variable for comparing linewidths between the two modalities is paired differences of measurements taken from the same patients. A paired t-test is used to test for a 50% decrease in the mean linewidth as measured by PFC-MRSI versus AIR-MRSI.
次要结局
未报告次要终点